Suscribirse

Evaluating augmentation with calcium phosphate cement (chronOS Inject) for bone defects after internal fixation of proximal tibial fractures: A prospective, multicenter, observational study - 08/02/17

Doi : 10.1016/j.otsr.2016.10.006 
C.W. Oh a , K.C. Park b, , Y.H. Jo b
a Department of Orthopedic Surgery, Kyungpook National University Hospital, 130 Dongduk-ro, Jung-gu, Daegu 41944, Republic of Korea 
b Department of Orthopedic Surgery, Hanyang University Guri Hospital, 153 Kyoungchun-ro, Guri-si, Gyeonggi-do 11923, Republic of Korea 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Introduction

Managing subchondral bone defects in proximal tibia fractures after plateau reduction is an important consideration. ChronOS Inject is a recently developed calcium phosphate bone substitute that shows relatively fast osteointegration.

Hypothesis

Using chronOS Inject during internal fixation of proximal tibial fractures provides a satisfactory treatment option that is both clinically and radiologically safe.

Patients and methods

Patients enrolled in this study were treated with chronOS Inject bone void filler, during internal fixation of proximal tibial fractures. Patients were evaluated preoperatively and at 6 weeks, 6 and 12 months postoperative. Radiographic union was assessed using plain films supplemented by CT scans. Pain, function and adverse events were collected at all visits. A total of 36 patients were enrolled in the study and treated according to a predetermined protocol. Seven of the 36 patients (19.4%) were lost to follow-up.

Results

Successful radiographic union was achieved in 27/29 (93.1%) of patients at final follow-up. Articular subsidence of>2mm only occurred in one patient. Statistical analysis showed significant improvements both in leg pain and knee function. Progress in knee function was observed in 93.1% (27/29) of patients from 6 weeks to 12 months. No product-related complications were reported.

Conclusions

Successful union was achieved based on radiographic criteria as well as clinical outcomes. When managing bone defects after internal fixation of proximal tibial fractures, the use of chronOS Inject resulted in significant improvement of knee function and reduction of leg pain.

Level of evidence

Level IV, prospective observational study.

El texto completo de este artículo está disponible en PDF.

Keywords : Proximal tibial fractures, Bone defect, Calcium phosphate cement


Esquema


© 2016  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 103 - N° 1

P. 105-109 - février 2017 Regresar al número
Artículo precedente Artículo precedente
  • Concurrent carpal tunnel syndrome and pronator syndrome: A retrospective study of 21 cases
  • C.-W. Hsiao, J.-T. Shih, S.-T. Hung
| Artículo siguiente Artículo siguiente
  • Does weight-bearing assignment after intramedullary nail placement alter healing of tibial shaft fractures?
  • D.A. Greenhill, M. Poorman, C. Pinkowski, F.V. Ramsey, C. Haydel

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.