Suscribirse

Normative 3D acetabular orientation measurements by the low-dose EOS imaging system in 102 asymptomatic subjects in standing position: Analyses by side, gender, pelvic incidence and reproducibility - 30/03/17

Doi : 10.1016/j.otsr.2016.11.010 
T. Thelen a, P. Thelen b, H. Demezon a, S. Aunoble a, J.-C. Le Huec a,
a Orthopedic and Spine Surgery Unit 2, Bordeaux University Hospital, Place Amélie-Raba-Léon, 33000 Bordeaux, France 
b RIM Maussins-Nollet, 114, Rue Nollet, 75017 Paris, France 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Background

Three-dimensional (3D) acetabular orientation is a fundamental topic in orthopedic surgery. Computed tomography (CT) allows 3D measurement of native acetabular orientation, but with a substantial radiation dose. The EOS imaging system was developed to perform this kind of evaluation, but has not been validated in this indication with specific attention to the acetabulum. We therefore performed a prospective study using EOS to assess: (1) the reproducibility of the 3D acetabulum orientation measures; (2) normative asymptomatic acetabular morphology in standing position, according to side and gender; and (3) the relationship between acetabular anteversion and pelvic incidence.

Hypothesis

The low-dose EOS imaging system is a reproducible method for measuring 3D acetabular orientation in standing position.

Patients and methods

In a previous prospective study of spine sagittal balance, 165 asymptomatic volunteers were examined on whole-body EOS biplanar X-ray; 102 had appropriate images for pelvic and acetabular analysis, with an equal sex-ratio (53 female, 49 male). These EOS images were reviewed using sterEOS 3D software, allowing automatic measurement of acetabular parameters (anteversion and inclination) and pelvic parameters (pelvic incidence, pelvic tilt and sacral slope) in an anatomical (anterior pelvic plane: APP) and a functional reference plane (patient vertical plane: PVP).

Results

Both intra- and inter-observer analysis showed good agreement (ICC>0.90); Bland–Altman plot distributions were good. Acetabular anatomical anteversion and inclination relative to APP (AAAPP and AIAPP, respectively) were significantly greater in women than in men, with no effect of side (right AAA: women 21.3°±3.4° vs. men 16.1°±3.3° (P<0001); right AIAPP: women 55.3°±3.7° vs. men 52.5°±3.0° (P<0001); left AAAPP: women 20.9°±3.5° vs. men 15.6°±4.0° (P<0001); left AIAPP: women 54.6°±3.5° vs. men 52.7°±2.8° (P=0003)).

The same differences between men and women were observed when measurements were related to PVP. Pelvic incidence subgroup (<44°; 44–62°; >62°) correlated significantly with functional acetabular orientation in standing position: PVP functional anteversion decreased by 5° relative to APP anteversion with incidence <44°, was equal to APP with incidence 44–62°, and or was greater by 4° relative to APP with incidence >62°.

Discussion

The use of a 3D sterEOS software prototype version for 3D reconstruction of the native acetabulum from standard EOS X-ray was shown to be a reliable and reproducible method. This innovative method enabled the reference values of 3D acetabular orientation in standing position to be measured for the first time. The results reinforced the concept of hip-spine relationships, and involved very low radiation dose.

Level of evidence

IV prospective study without control group.

El texto completo de este artículo está disponible en PDF.

Keywords : Native acetabulum, 3D orientation, Asymptomatic subjects, EOS


Esquema


© 2016  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 103 - N° 2

P. 209-215 - avril 2017 Regresar al número
Artículo precedente Artículo precedente
  • Development of a clinical path for the emergency care of hand bite injuries without signs of infection
  • A. Koutsomanis, J.J. Hidalgo Diaz, P. Vernet, F. Séverac, P. Liverneaux, S. Facca
| Artículo siguiente Artículo siguiente
  • Factors influencing progressive collapse of the transposed necrotic lesion after transtrochanteric anterior rotational osteotomy for osteonecrosis of the femoral head
  • Y. Kubo, G. Motomura, S. Ikemura, K. Sonoda, T. Yamamoto, Y. Nakashima

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.