Abstract

Background

Surgical stabilization of posterior pelvic ring fractures can be achieved by either open or closed methods. They all provide a comparable biomechanical stability. The aim of the present study is to compare the clinical results of both techniques for treating posterior pelvic ring injuries.

Material and methods

Seventy patients operated for unstable posterior pelvic ring disruptions were retrospectively reviewed. We compared 35 patients treated by open reduction internal fixation (ORIF group) versus 35 patients stabilized by using closed reduction and percutaneous iliosacral screw fixation (CRIF group) under fluoroscopic guidance.

Results

According to pelvic outcome scoring system of Pohlemann et al., 28 patients out of the ORIF group obtained good or excellent results (20 excellent and 8 good), five fair and two poor. In the CRIF group, 30 patients obtained good or excellent results (25 excellent and 5 good), four fair and one poor (P=0.64). The average intraoperative blood loss in the ORIF group was 500cc with average blood transfusion of 2units (1000cc) compared to blood loss 150cc in the CRIF group, with average blood transfusion of 1unit (500cc) (P=0.002). No intraoperative complications were reported in the ORIF group while operative guide wires were broken in two cases in the CRIF group (P=0.16). There were no neurological complications observed in the ORIF group, but one radiculopathy (L5 root palsy) occurred in the CRIF group (P=0.317). In the ORIF group, three patients had superficial wound infection and one patient had deep infection while in the CRIF group, we noted only one case of deep infection (P=0.083).

Conclusion

No difference was noticed between ORIF and CRIF. The technical decision is variable according to time of surgery, fracture types, patient general condition, skin condition, presence of ipsilateral fractures of the acetabulum and feasibility of the closed reduction. More studies are needed to identify prognostic factors related to quality of the reduction. We need for creation of decisional algorithm for ORIF versus CRIF.

Level of evidence

Level 4.

El texto completo de este artículo está disponible en PDF.

Keywords : Open reduction internal fixation, Closed reduction percutaneous fixation, Iliosacral screw fixation, Posterior pelvic ring disruption


Esquema


© 2016  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 103 - N° 2

P. 223-227 - avril 2017 Regresar al número
Artículo precedente Artículo precedente
  • Factors influencing progressive collapse of the transposed necrotic lesion after transtrochanteric anterior rotational osteotomy for osteonecrosis of the femoral head
  • Y. Kubo, G. Motomura, S. Ikemura, K. Sonoda, T. Yamamoto, Y. Nakashima
| Artículo siguiente Artículo siguiente
  • A new angle and its relationship with early fixation failure of femoral neck fractures treated with three cannulated compression screws
  • Y.L. Zhang, W. Zhang, C.Q. Zhang

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.