An international multicenter study comparing EUS-guided pancreatic duct drainage with enteroscopy-assisted endoscopic retrograde pancreatography after Whipple surgery - 20/04/17
Abstract |
Background and Aims |
Endoscopic management of post-Whipple pancreatic adverse events (AEs) with enteroscopy-assisted endoscopic retrograde pancreatography (e-ERP) is associated with high failure rates. EUS-guided pancreatic duct drainage (EUS-PDD) has shown promising results; however, no comparative data have been done for these 2 modalities. The goal of this study is to compare EUS-PDD with e-ERP in terms of technical success (PDD through dilation/stent), clinical success (improvement/resolution of pancreatic-type symptoms), and AE rates in patients with post-Whipple anatomy.
Methods |
This is an international multicenter comparative retrospective study at 7 tertiary centers (2 United States, 2 European, 2 Asian, and 1 South American). All consecutive patients who underwent EUS-PDD or e-ERP between January 2010 and August 2015 were included.
Results |
In total, 66 patients (mean age, 57 years; 48% women) and 75 procedures were identified with 40 in EUS-PDD and 35 in e-ERP. Technical success was achieved in 92.5% of procedures in the EUS-PDD group compared with 20% of procedures in the e-ERP group (OR, 49.3; P < .001). Clinical success (per patient) was attained in 87.5% of procedures in the EUS-PDD group compared with 23.1% in the e-ERP group (OR, 23.3; P < .001). AEs occurred more commonly in the EUS-PDD group (35% vs 2.9%, P < .001). However, all AEs were rated as mild or moderate. Procedure time and length of stay were not significantly different between the 2 groups.
Conclusions |
EUS-PDD is superior to e-ERP in post-Whipple anatomy in terms of efficacy with acceptable safety. As such, EUS-PDD should be considered as a potential first-line treatment in post-pancreaticoduodenectomy anatomy when necessary expertise is available.
El texto completo de este artículo está disponible en PDF.Abbreviations : AE, ASGE, CI, e-ERP, EUS-PDD, OR, PD
Esquema
| DISCLOSURE: The following authors disclosed financial relationships relevant to this publication: T. G. Moreels: Received prototype equipment for Olympus; M. A. Khashab: Consultant for Boston Scientific. All other authors disclosed no financial relationships relevant to this publication. |
Vol 85 - N° 1
P. 170-177 - janvier 2017 Regresar al númeroBienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.
¿Ya suscrito a @@106933@@ revista ?