Suscribirse

Lasso plate – An original implant for fixation of type I and II Regan-Morrey coronoid fractures - 21/04/17

Doi : 10.1016/j.otsr.2016.12.017 
P. Wang, Y. Zhuang, Z. Li, W. Wei, Y. Fu, X. Wei, K. Zhang
 Department of orthopedics and trauma, Xi’an Hong Hui Hospital, Xi’an Jiaotong University Health Science Center, No. 555, East Friendship Road, Xi’an City 710054, Shaanxi Province, China 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Introduction

Coronoid fractures are notoriously difficult to manage particularly when there is a small fragment. We report a retrospective analysis of our experience with consecutive type I and II Regan-Morrey coronoid fractures using a lasso plate.

Hypothesis

Type I and II Regan-Morrey coronoid fractures can be effectively managed using a lasso plate.

Methods

From October 2011 and December 2013, 25 patients (21 males and 4 females, mean age 40.0 years) with type I and II Regan-Morrey coronoid fractures were treated with the open reduction and internal fixation (ORIF) using the lasso plate. Postoperative measurements of the elbow range of motion were recorded. Elbow function was evaluated by the Mayo Elbow Performance Score (MEPS) and Disabilities of the Arm, Shoulder and Hand (DASH) score.

Results

All patients were reexamined at a mean follow-up of 32.7 months (range: 24–49 months). The mean fractures healing time was 13.6 weeks (range: 6 to 18 weeks). The mean flexion range of the elbow was 121.8° (range: 90° to 135°) and the mean extension range of the elbow was 10.6° (range: 0° to 20°). The mean pronation of the forearm was 75.8° (range: 65° to 85°). The mean supination of the forearm was 80.4° (range: 70° to 90°). The mean DASH score was 10.2 (range: 0 to 28). The mean MEPS was 83.4 (range: 55 to 95), 8 patients (32%) were rated excellent, 14 patients (56%) were rated good, 2 (8%) patients were rated fair. One (4%) patient was rated poor. No patient was seriously infected but implant breakage was found in one case. Two cases of elbow heterotopic ossification (HO) were observed. Two cases of elbow medial instability were observed.

Discussion

The type I and II Regan-Morrey coronoid fractures combined with the instability of the elbow should be operated. The lasso plate reduces the pressure between the wire and the insertion of capsule. A tight wire results in greater stability than ordinary suture fixation, thus enabling early functional exercise.

Conclusion

In the treatment of type I and II Regan-Morrey coronoid fractures, lasso plate can provide concentric fracture reduction of the elbow and stable fixation to allow for early rehabilitation. Good clinical outcomes can be anticipated.

Level of evidence

Level IV: retrospective study.

El texto completo de este artículo está disponible en PDF.

Keywords : Ulnar coronoid, Elbow, Fracture, Dislocation, Internal fixation, Lasso plate


Esquema


© 2017  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 103 - N° 3

P. 447-451 - mai 2017 Regresar al número
Artículo precedente Artículo precedente
  • Arthroscopic congruent-arc shoulder bone-block for severe glenoid bone defect: Preliminary report
  • J. Kany, B. Codanda, P. Croutzet, R. Guinand
| Artículo siguiente Artículo siguiente
  • Is there a relevance of suction drainage in non-septic wrist surgery?
  • G. Prunières, J.J. Hidalgo Diaz, P. Vernet, S. Salazar Botero, S. Facca, P.A. Liverneaux

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.