Suscribirse

Does semi-automatic bone-fragment segmentation improve the reproducibility of the Letournel acetabular fracture classification? - 18/08/17

Doi : 10.1016/j.otsr.2017.03.018 
M. Boudissa a, b, , B. Orfeuvre a, M. Chabanas b, J. Tonetti a, b
a Service de chirurgie orthopédique et traumatologique, hôpital Nord, université Grenoble Alpes, CHU Grenoble, boulevard de la Chantourne, 38700 La Tronche, France 
b CNRS UMR 5525, laboratoire TIMC-IMAG, pavillon Taillefer, université Grenoble Alpes, 38700 La Tronche, France 

Corresponding author at: Service de chirurgie orthopédique et traumatologique, hôpital Nord, université Grenoble Alpes, CHU Grenoble, boulevard de la Chantourne, 38700 La Tronche, France.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Background

The Letournel classification of acetabular fracture shows poor reproducibility in inexperienced observers, despite the introduction of 3D imaging. We therefore developed a method of semi-automatic segmentation based on CT data. The present prospective study aimed to assess: (1) whether semi-automatic bone-fragment segmentation increased the rate of correct classification; (2) if so, in which fracture types; and (3) feasibility using the open-source itksnap 3.0 software package without incurring extra cost for users.

Hypothesis

Semi-automatic segmentation of acetabular fractures significantly increases the rate of correct classification by orthopedic surgery residents.

Methods

Twelve orthopedic surgery residents classified 23 acetabular fractures. Six used conventional 3D reconstructions provided by the center's radiology department (conventional group) and 6 others used reconstructions obtained by semi-automatic segmentation using the open-source itksnap 3.0 software package (segmentation group). Bone fragments were identified by specific colors. Correct classification rates were compared between groups on Chi2 test. Assessment was repeated 2 weeks later, to determine intra-observer reproducibility.

Results

Correct classification rates were significantly higher in the “segmentation” group: 114/138 (83%) versus 71/138 (52%); P<0.0001. The difference was greater for simple (36/36 (100%) versus 17/36 (47%); P<0.0001) than complex fractures (79/102 (77%) versus 54/102 (53%); P=0.0004). Mean segmentation time per fracture was 27±3min [range, 21–35min]. The segmentation group showed excellent intra-observer correlation coefficients, overall (ICC=0.88), and for simple (ICC=0.92) and complex fractures (ICC=0.84).

Conclusion

Semi-automatic segmentation, identifying the various bone fragments, was effective in increasing the rate of correct acetabular fracture classification on the Letournel system by orthopedic surgery residents. It may be considered for routine use in education and training.

Level of evidence

III: prospective case-control study of a diagnostic procedure.

El texto completo de este artículo está disponible en PDF.

Keywords : Acetabular fractures, 3D reconstruction, Letournel classification, Segmentation


Esquema


© 2017  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 103 - N° 5

P. 633-638 - septembre 2017 Regresar al número
Artículo precedente Artículo precedente
  • Recent progress in the diagnosis and treatment of pelvic ring and acetabular fracture
  • J. Tonetti, P. Jouffroy, Pelvis-Acetabulum Club 1
| Artículo siguiente Artículo siguiente
  • Injury of the obturator nerve in the modified Stoppa approach for acetabular fractures
  • J.W. Kim, H.C. Shon, J.H. Park

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.