Suscribirse

High-Sensitivity Troponin Release Profile After Cardiac Surgery - 27/09/17

Doi : 10.1016/j.hlc.2016.09.017 
Phuong L. Markman, MBBS a, John-Paul Tantiongco, BMBS a, b, Jayme S. Bennetts, FRACS a, b, Robert A. Baker, PhD a, b, ⁎
a Flinders Medical Centre, Adelaide, SA, Australia 
b Flinders University, Adelaide, SA, Australia 

⁎Corresponding author at: Cardiac Surgery Research and Perfusion, Flinders Medical Centre and Flinders University, Level 6 Flinders Private Hospital, Flinders Drive, Bedford Park 5042, Australia. Phone: +61 8 8404 2015; Fax: +61 8 8404 2019

Resumen

Background

Postoperative serum troponin levels and perioperative myocardial infarction (MI) rates correlate with mortality and morbidity following cardiac surgery. The objective of this study was to document the release profile of high sensitivity troponin T (hsTnT) following different cardiac operations.

Methods

Patients undergoing one of five different isolated cardiac surgical procedures (eligible preoperative hsTnT <29ng/L, serum creatinine < 0.2mmol/L) were recruited prospectively. Serum hsTnT was measured at 0, 4, 6, 8, 10, 12, 24 and 72hours after the first surgical insult to myocardium, together with daily electrocardiographs.

Results

There were 10 patients in the on-pump coronary artery bypass group and 5 each in the remaining groups (off-pump coronary artery bypass, open aortic valve replacement, transcutaneous aortic valve implantation and mitral valve replacement). Five additional patients were excluded due to perioperative MI or renal failure. Median [range] of peak hsTnT was 241[99–566], 64[50–136], 353[307–902], 115[112–275], and 918[604–1166] ng/L, respectively. Operations with the lowest peak hsTnT values peaked earliest (four hours) while those with highest values peaked latest (eight hours).

Conclusion

After cardiac surgery, the hsTnT profile peaks four to eight hours after the initial surgical insult. The magnitude and timing of the peak correlates to the expected degree of surgically-induced myocardial injury.

El texto completo de este artículo está disponible en PDF.

Keywords : Troponin, Troponin T, Perioperative period, Cardiac surgical procedures, Myocardial revascularisation, Heart valve prosthesis implantation


Esquema


© 2017  Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Publicado por Elsevier Masson SAS. Todos los derechos reservados.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 26 - N° 8

P. 833-839 - août 2017 Regresar al número
Artículo precedente Artículo precedente
  • Cardiac Troponin T as Early Marker of Subclinical Cardiovascular Deterioration in Black Hypertensive Women
  • R. Kruger, A.E. Schutte, C.M.C. Mels, W. Smith, J.M. van Rooyen, I.M. Kruger, C.M.T. Fourie
| Artículo siguiente Artículo siguiente
  • Transcatheter Versus Surgical Aortic Valve Replacement in Patients With Lower Surgical Risk Scores: A Systematic Review and Meta-Analysis of Early Outcomes
  • Sameer Arora, Paula D. Strassle, Cassandra J. Ramm, Jeremy A. Rhodes, Satyanarayana R. Vaidya, Thomas G. Caranasos, John P. Vavalle

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.