A novel device for improving visualization in an inadequately prepared colon - 21/02/18

Doi : 10.1016/j.gie.2017.10.028 
Seth A. Gross, MD 1, , Lauren B. Gerson, MD 2 : deceased, Blair S. Lewis, MD 3, Robert A. Ganz, MD 4
1 Tisch Hospital, NYU Langone Medical Center, New York, New York, USA 
2 California Pacific Medical Center, San Francisco, California, USA 
3 Carnegie Hill Endoscopy, New York, New York, USA 
4 Minnesota Gastroenterology P.A., Minnesota, USA 

Reprint requests: Seth A. Gross, MD, FASGE, Chief of Gastroenterology, Tisch Hospital, Associate Professor of Medicine, NYU Langone Medical Center, New York, NY 10016.Chief of GastroenterologyTisch HospitalAssociate Professor of MedicineNYU Langone Medical CenterNew YorkNY10016

Abstract

Background and Aims

Adequate bowel preparation is crucial for a quality colonoscopy. Poor bowel preparation can result in longer procedural times, missed adenomas, earlier repeat procedures, increase costs, and decreased patient satisfaction. Pure-Vu (MOTUS GI, Tirat Carmel, Israel) is a system that facilitates intraprocedural cleaning of a poorly prepared colon during a colonoscopy by irrigating the colon and evacuating the fluid and feces. The study aims were to evaluate Pure-Vu’s cleansing capabilities and its usability and safety in a live animal colon.

Methods

The Pure-Vu system was used by 4 experienced gastroenterologists in 35 Yorkshire cross swine (66% female) that received a reduced bowel preparation to ensure an inadequate bowel preparation at baseline. Before colonoscopy the Pure-Vu was attached to the colonoscope, and the baseline prep was assessed during insertion. The Pure-Vu system was then used to cleanse the colon and the prep then assessed after Pure-Vu use.

Results

No adverse effects and no failed or prematurely terminated cases were noted. Fourteen percent of the swine colons were adequately prepped at baseline (median Boston Bowel Preparation Scale [BBPS] score = 0 [25th percentile = 0; 75th percentile = 1; interquartile range = 1]) and improved to 100% after use of Pure-Vu (Wilcoxon signed rank test P < .001) (median BBPS score = 3 [25th percentile = 3; 75th percentile = 3; interquartile range = 0]). The physicians found Pure-Vu easy and intuitive to operate.

Conclusions

The Pure-Vu system effectively cleaned inadequately prepped swine colons and proved to be easy to use. The Pure-Vu device, applied in clinical practice, may result in improved overall prep quality and a reduction in repeat examinations because of inadequately prepped colons.

El texto completo de este artículo está disponible en PDF.

Abbreviations : BBPS, IQR


Esquema


 DISCLOSURE: All authors disclosed no financial relationships relevant to this publication.
 If you would like to chat with an author of this article, you may contact Dr Gross at Seth.Gross@nyumc.org.


© 2018  American Society for Gastrointestinal Endoscopy. Publicado por Elsevier Masson SAS. Todos los derechos reservados.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 87 - N° 3

P. 883-888 - mars 2018 Regresar al número
Artículo precedente Artículo precedente
  • Rectal EMR for enteric ganglia: Is deeper better?
  • Christine Yu, Satish S.C. Rao
| Artículo siguiente Artículo siguiente
  • A novel method to prevent catheter dysfunction during spray cryotherapy
  • Kavel Visrodia, Liam Zakko, Theresa Nolte, Kenneth K. Wang

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.