Suscribirse

Differences in trochlear parameters between native and prosthetic kinematically or mechanically aligned knees - 31/03/18

Doi : 10.1016/j.otsr.2017.10.009 
C. Rivière a, , F. Iranpour a, S. Harris a, E. Auvinet a, A. Aframian a, S. Parratte b, J. Cobb a
a MSK Lab, Charing Cross Hospital, Imperial College London, W6 8RP London, UK 
b Service de chirurgie orthopédique, hôpital Sainte-Marguerite, université Aix-Marseille, 13009 Marseille, France 

Corresponding authorCharring Cross Hospital, Joint replacement, Fulham Palace Road, W6 8RF London, UK

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Introduction

Kinematic (KA) and mechanical (MA) alignment techniques are two different philosophies of implant positioning that use the same TKA implants. This might generate differences in the resulting prosthetic trochleae parameters between the two techniques of alignment. Our study aim was to test the following hypotheses : (1) mechanically or kinematically aligned femoral implant understuffs the native trochlear articular surface and poorly restores the native groove orientation, and (2) the orientation of the prosthetic trochlear groove and trochlear fill are different between MA and KA.

Methods

Three-dimensional models of the femur were made from segmentation of preoperative Magnetic Resonance Imaging scans (MRIs) of ten subjects with isolated medial tibiofemoral osteoarthritis. In-house planning and analysis software kinematically and mechanically aligned a modern cruciate retaining femoral component and determined differences in parameters of the trochlear fit between native and prosthetic trochleae, and between KA and MA prosthetic trochleae.

Results

The MA prosthetic trochleae did not fill (understuffed) the entire length of the native medial facet and the proximal 70% of the native groove and lateral facet, and oriented the trochleae groove 8° more valgus than native. The KA prosthetic trochleae understuffed the proximal 70% of the native trochleae, and had a groove 6° more valgus than native. The KA trochleae understuffed the medial facet distally and oriented the groove 2° less valgus and 3° more internally rotated than the MA trochleae.

Conclusion

MA and KA prosthetic trochleae substantially understuff and create a prosthetic groove more valgus compared to native trochlear anatomy, and they also differed between each other regarding trochleae stuffing and groove alignment. Although randomized trials have not shown differences in patellofemoral complications between KA and MA, a femoral component designed specifically for KA that more closely restores the native trochlear anatomy might improve patient reported satisfaction and function.

Level of evidence

Level 2 controlled laboratory study.

El texto completo de este artículo está disponible en PDF.

Keywords : Kinematic alignment, Total knee arthroplasty, Trochleae, Stuffing


Esquema


© 2017  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 104 - N° 2

P. 165-170 - avril 2018 Regresar al número
Artículo precedente Artículo precedente
  • Ten-year survival and complications of total knee arthroplasty for osteoarthritis secondary to trauma or surgery: A French multicentre study of 263 patients
  • S. Putman, J.-N. Argenson, P. Bonnevialle, M. Ehlinger, P. Vie, S. Leclercq, P. Bizot, S. Lustig, S. Parratte, N. Ramdane, M. Colmar, the Société française de chirurgie orthopédique et traumatologie (SOFCOT) k
| Artículo siguiente Artículo siguiente
  • Comparison of mode of failure between primary and revision total knee arthroplasties
  • H. Liang, J.K. Bae, C.H. Park, K.I. Kim, D.K. Bae, S.J. Song

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.