Multidetector computed tomography sizing of aortic annulus prior to transcatheter aortic valve replacement (TAVR): Variability and impact of observer experience - 09/05/18

Doi : 10.1016/j.diii.2017.12.007 
S. Le Couteulx a, J. Caudron a, b, B. Dubourg a, b, G. Cauchois a, c, M. Dupré c, P. Michelin a, E. Durand b, c, H. Eltchaninoff b, c, J.-N. Dacher a, c,
a Department of Radiology, Cardiac MR/CT Unit, Rouen University Hospital, 1, rue de Germont, 76031 Rouen cedex, France 
b Inserm U1096, Normandie University UNIROUEN, 22, boulevard Gambetta, 76000 Rouen, France 
c Department of Cardiology, Rouen University Hospital, 1, rue de Germont, 76031 Rouen cedex, France 

Corresponding author. Department of Radiology, Cardiac MR/CT Unit, Rouen University Hospital, 1, rue de Germont, 76031 Rouen cedex, France.Department of Radiology, Cardiac MR/CT Unit, Rouen University Hospital, 1, rue de Germont, 76031 Rouen cedex, France.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Purpose

To evaluate intra- and inter-observer variability of multidetector computed tomography (MDCT) sizing of the aortic annulus before transcatheter aortic valve replacement (TAVR) and the effect of observer experience, aortic valve calcification and image quality.

Methods

MDCT examinations of 52 consecutive patients with tricuspid aortic valve (30 women, 22 men) with a mean age of 83±7 (SD) years (range: 64–93 years) were evaluated retrospectively. The maximum and minimum diameters, area and circumference of the aortic annulus were measured twice at diastole and systole with a standardized approach by three independent observers with different levels of experience (expert [observer 1]; resident with intensive 6 months practice [observer 2]; trained resident with starting experience [observer 3]). Observers were requested to recommend the valve prosthesis size. Calcification volume of the aortic valve and signal to noise ratio were evaluated.

Results

Intra- and inter-observer reproducibility was excellent for all aortic annulus dimensions, with an intraclass correlation coefficient ranging respectively from 0.84 to 0.98 and from 0.82 to 0.97. Agreement for selection of prosthesis size was almost perfect between the two most experienced observers (k=0.82) and substantial with the inexperienced observer (k=0.67). Aortic valve calcification did not influence intra-observer reproducibility. Image quality influenced reproducibility of the inexperienced observer.

Conclusion

Intra- and inter-observer variability of aortic annulus sizing by MDCT is low. Nevertheless, the less experienced observer showed lower reliability suggesting a learning curve.

El texto completo de este artículo está disponible en PDF.

Keywords : Multidetector computed tomography (CT), Aorta, Heart, Aortic valve stenosis, Observer variation


Esquema


© 2017  Publicado por Elsevier Masson SAS.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 99 - N° 5

P. 279-289 - mai 2018 Regresar al número
Artículo precedente Artículo precedente
  • Comparison of enhancement of the vestibular perilymph between gadoterate meglumine and gadobutrol at 3-Tesla in Meniere's disease
  • M. Eliezer, G. Poillon, A. Gillibert, J. Horion, Y. Cruypeninck, E. Gerardin, N. Magne, A. Attyé
| Artículo siguiente Artículo siguiente
  • CT-texture analysis of subsolid nodules for differentiating invasive from in-situ and minimally invasive lung adenocarcinoma subtypes
  • J.G. Cohen, E. Reymond, M. Medici, M. Lederlin, S. Lantuejoul, F. Laurent, A.C. Toffart, A. Moreau-Gaudry, A. Jankowski, G.R. Ferretti

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.