High-resolution EEG (HR-EEG) allows the recording of electric brain activities with excellent temporal resolution. Data have to be recorded with high temporal resolution (sampling rate) and high spatial resolution (number of channels). Data analyses are based on several steps including interictal and/or ictal selections, head model elaboration and use of several algorithms in order to solve the inverse problem. These tools now represent real methods of Electric Source Imaging. HR-EEG constitutes non-invasive and complementary examination with Magnetoencephalography (MEG), characterized by distinct sensitivities according to the location and orientation of intracerebral generators. In the presurgical assessment of drug-resistant partial epilepsies, HR-EEG can characterize and localize interictal activities and thus the irritative zone. HR-EEG often yields significant additional data that are complementary to other presurgical investigations. In some lesional epilepsy cases as epilepsies related to focal cortical dysplasia, localization of the irritative zone using HR-EEG is particularly relevant in presurgical evaluation, epileptogenic and irritative zones being characterized by an overlap. It has been demonstrated that HR-EEG more accurately estimated the epileptogenic zone in subgroups of patients who are often the most difficult cases in epilepsy surgery: frontal lobe epilepsy, negative MRI and the presence of malformation of cortical development [1]. Moreover, source localization results may help in identifying subtle focal cortical dysplasia abnormalities and increasing the diagnostic yield of conventional MRI visual analysis [3]. During presurgical evaluation of pharmacoresistant partial epilepsies, stereoelectroencephalography records interictal and ictal activities directly but is inherently limited in spatial sampling. In contrast, scalp-EEG and MEG are less sensitive but provide a global view on brain activity. Therefore, recording simultaneously these three modalities [2] should provide a better understanding of the underlying brain sources by taking advantage of the different sensitivities of the three recording techniques.

El texto completo de este artículo está disponible en PDF.

Keywords : Epilepsy, Interictal spikes, Pre-surgical investigation


Esquema


© 2018  Publicado por Elsevier Masson SAS.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 48 - N° 4

P. 230 - septembre 2018 Regresar al número
Artículo precedente Artículo precedente
  • Description des caractéristiques EEG d’une série de 6 patients diagnostiqués pour une encéphalite dysimmunitaire
  • Arnaud Gagnol, Marie De Montaudouin
| Artículo siguiente Artículo siguiente
  • Altération de la perception visuelle élémentaire en psychiatrie
  • Anne Giersch

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.