Suscribirse

Total hip arthroplasty after failed fixation of a proximal femur fracture: Analysis of 59 cases of intra- and extra-capsular fractures - 22/08/18

Doi : 10.1016/j.otsr.2018.04.015 
Antoine Morice a, , Florian Ducellier b, Pascal Bizot c
the

Orthopaedics and Traumatology Society of Western France (SOO)d

a Service de chirurgie orthopédique et traumatologique, centre hospitalier d’Agen-Nerac, Route de Villeneuves sur Lot, 47923 Agen, France 
b Service de chirurgie orthopédique et traumatologique, CHU d’Angers, 4, rue Larrey, 49100 Angers, France 
c Service de chirurgie orthopédique et traumatologique, CHU de Lariboisière, université Paris-Diderot, AP–HP, 2, rue Ambroise-Paré, 75475 Paris, France 
d SOO - Société d’orthopédie de l’ouest, 18, rue de Bellinière, 49800 Trélazé, France 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Introduction

The indications for total hip arthroplasty (THA) after failed internal fixation of a proximal femur fracture vary. Published studies on this topic are broad-ranging and do not distinguish between intracapsular and extracapsular fractures. This led us to conduct a retrospective analysis comparing the clinical outcomes, radiological outcomes, technical problems and complications between these two types of fractures.

Hypothesis

The functional outcomes of THA after an extracapsular fracture will be worse than the ones after an intracapsular fracture.

Material and methods

This was a retrospective, single-center study of 59 THA cases performed after internal fixation of a proximal femur fracture. These procedures were performed between 2002 and 2013 in 58 patients (22 men, 36 women). There were 40 intracapsular fractures and 19 extracapsular fractures. The initial fracture fixation involved a screw-plate (n=50), intramedullary nail (n=6) or screws (n=3). The mean patient age at the time of THA was 67 years [22–94]. The THA was performed an average of 2.8 years [0.2–28] after the fracture. The posterolateral approach was used in 55 cases (93%). Ten patients (17%) had the fixation hardware removed before the THA procedure, on average at 30 months [1–240] after the fracture. During the THA procedure, a cemented stem was used in 31 cases (53%) and a cementless stem in 28 cases (47%). A cementless press-fit cup was used in 56 cases (95%), of which 35 were dual mobility cups (60%), and a cemented cup was used in the other 3 cases (5%). All patients were reviewed by a physician not involved in the surgical procedures who performed a clinical and radiological examination.

Results

No patients were lost to follow-up; two patients died. Ten patients suffered an intraoperative femur fracture (17%) and four suffered a dislocation (2 early, 2 late) (6.8%). Nine hips had to be reoperated (15%), of which five required an implant change (8.5%). There were significantly more intraoperative fractures and postoperative complications in the THA cases after extracapsular fracture. With a mean follow-up of 38 months [12–149], the mean PMA and Harris scores were 14.6 [3–18] and 74 [10–100], respectively; these scores were significantly lower in the THA cases after extracapsular fracture (p<0.05). With an endpoint of revision with implant change, the overall 40-month survival was 94% (95% CI: 0.25–0.55); it was 97% (95% CI: 0.62–0.85) for the intracapsular fracture cases and 84% (95% CI: 0.39–0.75) for the extracapsular fracture cases (p<0.05).

Conclusion

Secondary THA after failed fixation of proximal femur fractures has more complications than primary THA. Subgroup analysis identified more technical problems in the THA cases after extracapsular fracture and a higher number of complications, particularly dislocation and periprosthetic fractures.

Level of evidence

IV – Retrospective study.

El texto completo de este artículo está disponible en PDF.

Keywords : Total hip arthroplasty, Internal fixation, Proximal femur fracture


Esquema


 Article issued from the Orthopaedics and Traumatology Society of Western France (SOO) – 2017 Tours meeting.


© 2018  Publicado por Elsevier Masson SAS.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 104 - N° 5

P. 681-686 - septembre 2018 Regresar al número
Artículo precedente Artículo precedente
  • Medial acetabular wall breach in total hip arthroplasty – is full-weight-bearing possible?
  • Filippo Mandelli, Simon Tiziani, Jürgen Schmitt, Clément M.L. Werner, Hans-Peter Simmen, Georg Osterhoff
| Artículo siguiente Artículo siguiente
  • The influence of bone cement and American Society of Anesthesiologists (ASA) class on cardiovascular status during bipolar hemiarthroplasty for displaced femoral-neck fracture: A multicenter, prospective, case-control study
  • Shuichi Miyamoto, Junichi Nakamura, Satoshi Iida, Tomonori Shigemura, Shunji Kishida, Isao Abe, Munenori Takeshita, Makoto Otsuka, Yoshitada Harada, Sumihisa Orita, Seiji Ohtori

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.