Suscribirse

Wide volume versus helical acquisition using 320-detector row computed tomography for computed tomography urography in adults - 19/10/18

Doi : 10.1016/j.diii.2018.05.009 
C. Roy a, , R. Quin a, A. Labani a, P. Leyendecker a, L. Mertz b, M. Ohana a
a Department of Radiology B, University Hospital of Strasbourg–Hôpital Civil 1, place de l’hôpital, 67091 Strasbourg cedex, France 
b Medical Physics Department, University Hospital of Strasbourg–Hôpital Civil 1, place de l’hôpital, BP 426, 67091 Strasbourg cedex, France 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Purpose

To evaluate the best collimation used in wide volume (WV) mode to cover the abdomen in computed tomography (CT) urography in terms of radiation dose and image quality.

Materials and methods

This study was performed on a 320×0.5mm detector row CT unit. The first part identified the lowest volume CT dose index (CTDIvol) by using the topograms data of 25 medium size patients (13 men and 12 women; mean age: 52±9 [SD] years; age range: 46–68 years) using different collimations on WV from 6cm to 16cm and the one of the helical mode for the same coverage length. The second part consisted of a clinical evaluation of this result including 45 medium size patients (32 men and 13 women; mean age: 68±14 [SD] years; age range: 45–72 years). The qualitative evaluation included several items based on a 5-point Likert scale.

Results

The first part of the study indicated that a collimation of 10cm (200×0.5mm) in WV mode with 5 volumes had the lowest CTDIvol (2.78±0.35mGy; range: 2.35–3.21mGy) compared to helical mode (4.38±0.48mGy, range: 3.75–4.95mGy). In the second part, the mean radiation dose reduction by comparison with helical mode was 44.03%±0.36% (P<0.001) and 51.16%±1.22% (P<0.005) for CTDIvol and DLP, respectively.

Conclusion

Wide volume mode of the abdomen can be performed with a significant radiation dose reduction with a collimation of 10cm (200×0.5mm) and five volumes.

El texto completo de este artículo está disponible en PDF.

Keywords : Multidetector computed tomography (MDCT), Radiation dose reduction, Wide-volume CT, Helical CT optimization

Abbreviations : CTDIvol


Esquema


© 2018  Soci showét showé françaises de radiologie. Publicado por Elsevier Masson SAS. Todos los derechos reservados.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 99 - N° 10

P. 653-662 - octobre 2018 Regresar al número
Artículo precedente Artículo precedente
  • Predicting prognosis of resected hepatocellular carcinoma by radiomics analysis with random survival forest
  • H. Akai, K. Yasaka, A. Kunimatsu, M. Nojima, T. Kokudo, N. Kokudo, K. Hasegawa, O. Abe, K. Ohtomo, S. Kiryu
| Artículo siguiente Artículo siguiente
  • Doppler ultrasound in the diagnosis of Budd-Chiari syndrome in children after split liver transplantation
  • J.F. Hak, A. Dabadie, G. Hery, A. Aschero, C. Desvignes, H. Pico, B. Roquelaure, A. Delarue, B. Bourliere, N. Colavolpe, G. Gorincour, P. Auquier, P. Petit

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.