Abstract

Background

Procedure volume is an important determinant of total knee arthroplasty (TKA) outcomes. We aimed to determine whether computer navigation or patient-specific instrumentation (PSI) would improve postoperative alignment in a low-volume setting.

Hypothesis

PSI for TKA achieves better limb and implant alignment compared to conventional TKA and to computer navigated TKA.

Materials and methods

This is a retrospective cohort study of 385 primary TKAs (Women=59%. Mean age=67years. Mean BMI=30.1kg/m2), which were performed using conventional instrumentation (n=117; 30%), computer navigation (n=209; 54%), or patient-specific instrumentation (n=59; 15%) in a low-volume center (<50 TKAs/year). The risk of postoperative leg and implant mechanical alignment outliers in the coronal plane (>3° from neutral), average alignment and operation time were assessed.

Results

The risk of postoperative mechanical alignment outliers (>3°) was reduced by 89% in the navigated group (4% outliers) compared to the conventional group (35%) (RR=0.11; p<0.0001). No significant improvement was observed in the PSI group (27%) (RR=0.91; p=0.772). The risk of postoperative femoral component coronal alignment outliers was reduced by 63% in the navigated group (11%) compared to the conventional group (31%) (RR=0.37; p=0.018). No significant reduction in outliers was observed in the PSI group (32%) (RR=1.08; p=0.816). There was a reduction in the risk of tibial component coronal malalignment of 66% in the navigated group (5%) compared to the conventional group (13%) (RR=0.33; p=0.070). There was a two-fold increase in the risk of tibial component alignment outliers in the PSI group (29%) (RR=1.94; p=0.110).

Discussion

Computer navigation improved postoperative alignment in TKA. No evidence of improved alignment was seen with patient-specific instrumentation. The routine use of patient-specific instrumentation in low-volume centers is not supported by the currently available data.

Type of study

Retrospective cohort study. Level IV.

El texto completo de este artículo está disponible en PDF.

Keywords : Knee, Total knee Arthroplasty, Patient-specific TKA, Computer navigation, Low-volume, Alignment


Esquema


© 2018  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 104 - N° 7

P. 971-975 - novembre 2018 Regresar al número
Artículo precedente Artículo precedente
  • Outpatient total knee arthroplasty: Readmission and complication rates on day 30 in 61 patients
  • Xavier Cassard, Valérie Garnault, Boris Corin, Denis Claverie, Jérôme Murgier
| Artículo siguiente Artículo siguiente
  • Predictability of open superficial medial collateral ligament lengthening technique in total knee arthroplasty. Comparison of multiple needle puncturing and subperiosteal elevation: A cadaver study
  • Khanin Iamthanaporn, Alan Geater, Varah Yuenyongviwat

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2025 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.