Are dual mobility cups associated with increased metal ions in the blood? Clinical study of nickel and chromium levels with 29 months’ follow-up - 23/11/18

Doi : 10.1016/j.otsr.2018.08.012 
Laura Marie-Hardy , Padhraig O’Laughlin, Michel Bonnin, Tarik Ait Si Selmi
 Centre orthopédique Paul-Santy-Mermoz, 24, avenue Paul-Santy, 69008 Lyon, France 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Introduction

Dual mobility cups have become the implant of choice for older patients with a high risk of dislocation. However, to our knowledge, no study has explored the possibility of metal ion production with these implants that incorporate a polyethylene-on-metal bearing. This led us to conduct a prospective study to determine whether use of a dual mobility cup is accompanied by increased levels of nickel and chromium in the blood.

Hypothesis

Use of a dual mobility cup is accompanied by an increase of nickel and chromium levels in the blood.

Methods

Between 2012 and 2015, 16 consecutive patients were enrolled in the study. They underwent primary hip arthroplasty with a ceramic Biolox™ head (CeramTec, Plochingen, Germany), Corail™ titanium alloy stem (DePuy Synthes, Saint Priest, France) and a Novae™ dual mobility cup (SERF, Décines-Charpieu, France) consisting of 19% chromium (Cr) and 13–15% nickel (Ni). Patients who had other potential sources of nickel or chromium in their body (joint implants, dental implants, etc.) were excluded. The blood levels (μg/L) of nickel and chromium were measured preoperatively and at 2 years’ follow-up by an independent laboratory (Biomnis) using inductively coupled plasma mass spectrometry. The upper limits set by the laboratory were<0.87μg/L for chromium and<1.0μg/L for nickel. AP and lateral X-rays of the pelvis were taken preoperatively and at each postoperative follow-up visit to look for signs of loosening. The Postel-Merle-d’Aubigné (PMA) score was determined preoperatively and at each postoperative follow-up visit. Surgical revision procedures for any cause were also documented.

Results

The mean follow-up was 29 months [13–39]. Preoperatively, blood nickel ion levels were measured in 7 patients; they were below 1μg/L in 6 patients (86%) and at 1.5μg/L in 1 patient (14%). The mean preoperative chromium ion levels (n=7) was 0.2μg/L [0–0.8μg/L]. Postoperatively, all 16 enrolled patients had their blood ion levels checked at a mean follow-up of 29 months. The nickel ion levels averaged 1.69±1.49 [0.2–5.6] (with 4/16 having>2μg/L and 12/16>1μg/L) and the chromium ion levels averaged 0.5±0.11 [0.4–0.7] (with no patients>0.7μg/L). There were no signs of loosening or osteolysis on the follow-up radiographs. The mean PMA score at 2 years was 17.8 [17,18].

Conclusion

We found that dual mobility cups generate increased nickel but not chromium ions in the blood. The levels measured are comparable to those for other orthopedic implants such as spine implants. The clinical consequences of these increased levels are not known. Nevertheless, there were no clinical or radiological signs of loosening, although the follow-up was only 2 years.

Level of evidence

IV, Cohort study.

El texto completo de este artículo está disponible en PDF.

Keywords : Hip replacement, Double mobility, Public health, Nickel, Chromium


Esquema


© 2018  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 104 - N° 8

P. 1179-1182 - décembre 2018 Regresar al número
Artículo precedente Artículo precedente
  • The Merete BioBall system in hip revision surgery: A systematic review
  • Carlos D. Novoa, Mustafa Citak, Akos Zahar, Roxana E. López, Thorsten Gehrke, José L. Rodrigo
| Artículo siguiente Artículo siguiente
  • Risk factors for cut-out after internal fixation of trochanteric fractures in elderly subjects
  • Antoine Morvan, Jacques Boddaert, Judith Cohen-Bittan, Hervé Picard, Hugues Pascal-Mousselard, Frédéric Khiami

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.