Suscribirse

Breast mass characterization using shear wave elastography and ultrasound - 19/12/18

Doi : 10.1016/j.diii.2018.06.002 
S. Hari a, S.B. Paul a, , R. Vidyasagar a, E. Dhamija a, A.D. Adarsh a, S. Thulkar a, S. Mathur b, V. Sreenivas c, S. Sharma a, A. Srivastava d, V. Seenu d, R. Prashad d
a Department of Radiology, All India Institute of Medical Sciences, 110029 New Delhi, India 
b Departments of Pathology, All India Institute of Medical Sciences, 110029 New Delhi, India 
c Departments of Biostatistics, All India Institute of Medical Sciences, 110029 New Delhi, India 
d Departments of Surgery, All India Institute of Medical Sciences, 110029 New Delhi, India 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Purpose

To evaluate the role of SWE in characterizing breast masses and ascertain whether additional use of SWE to ultrasound for evaluating BI-RADS 3 and 4a masses could help reduce long-term follow-up and unnecessary biopsies of these suspicious breast masses.

Materials and methods

This prospective, cross-sectional study was performed between June 2013 and November 2014. All enrolled patients underwent clinical breast examination, ultrasound, SWE and ultrasound-guided core biopsy of the breast mass. Breast Imaging Reporting and Data System (BI-RAD) categories were assigned to breast masses. For qualitative and quantitative variables of SWE, cut-off values for differentiation between benign and malignant breast masses were estimated. Modified BIRADS’ (up/downgrading of BIRADS category) was done for BI-RADS 3/4a masses by combining individual SWE parameters and ultrasound findings. Sensitivity, specificity, positive and negative predictive value of modified BI-RADS’ and ultrasound BI-RADS were compared.

Results

A total of 119 women (mean age, 42.3±13.6 [SD] years; range: 13–87 years) with a single breast mass each were enrolled. Histopathologically, 57/119 (48%) breast masses were benign and 62 (52%) were malignant. On ultrasound, 42 breast masses were BI-RADS3 and 77 were BI-RADS 4 (4a, n=10; 4b, n=24; 4c, n=43) leading to 96.8% sensitivity and 70.2% specificity. On SWE, benign breast masses were oval/round, homogenous/reasonably homogenous, blue/green with lower elasticity values and malignant breast masses were irregular, inhomogeneous, red/orange with high elasticity values. On modified BI-RADS’ using E-color and E-mean/E-max, specificity improved to 78.9% and 75.4% respectively.

Conclusion

Addition of SWE to ultrasound improves characterization of BI-RADS 3 and 4a masses. E-max, E-mean and E-color are the most useful SWE parameters to differentiate between malignant and benign breast masses.

El texto completo de este artículo está disponible en PDF.

Keywords : Shear wave elastography, Ultrasound, Breast mass, Image analysis


Esquema


© 2018  Soci showét showé françaises de radiologie. Publicado por Elsevier Masson SAS. Todos los derechos reservados.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 99 - N° 11

P. 699-707 - novembre 2018 Regresar al número
Artículo precedente Artículo precedente
  • Distribution of left ventricular trabeculation across age and gender in 140 healthy Caucasian subjects on MR imaging
  • Z. Bentatou, M. Finas, P. Habert, F. Kober, M. Guye, S. Bricq, A. Lalande, J. Frandon, JN. Dacher, B. Dubourg, G. Habib, J. Caudron, S. Normant, S. Rapacchi, M. Bernard, A. Jacquier
| Artículo siguiente Artículo siguiente
  • Artificial intelligence assistance for fetal head biometry: Assessment of automated measurement software
  • G. Ambroise Grandjean, G. Hossu, C. Bertholdt, P. Noble, O. Morel, G. Grangé

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.