Suscribirse

Predictors and Changes in Cardiac Hemodynamics and Geometry With Transcatheter Aortic Valve Implantation - 08/02/19

Doi : 10.1016/j.amjcard.2018.11.038 
Fawaz Alenezi, MD, MSc a, b, Marat Fudim, MD a, Jennifer Rymer, MD a, Allison Dunning, MS b, Karen Chiswell, PhD b, Madhav Swaminathan, MD c, Brandi Bottiger, MD c, Poonam Velagapudi, MD d, Alina Nicoara, MD c, Joseph Kisslo, MD a, Eric Velazquez, MD a, Sreekanth Vemulapalli, MD a, Gerald S. Bloomfield, MD, MPH a, b, Zainab Samad, MD, MHS e, ⁎
a Division of Cardiology, Department of Medicine, Duke University, Durham, North Carolina 
b Duke Clinical Research Institute, Duke University, Durham, North Carolina 
c Division of Anesthesiology, Duke University, Durham, North Carolina 
d Division of Cardiology, University of Nebraska Medical Center, Omaha, Nebraska 
e Aga Khan University, Karachi, Pakistan 

⁎Corresponding author: Tel: (919) 668-1524; fax: (919) 668-3575.

Resumen

The introduction of transcatheter aortic valve implantation (TAVI) has revolutionized the treatment of patients with severe aortic stenosis (AS). However, despite the great clinical success of TAVI, less is known about the cardiac hemodynamics and structural changes to post-TAVI. We analyzed patients with AS who had a transthoracic echocardiography at most 6 months before index TAVI and follow-up transthoracic echocardiography 9 to 18 months later, performed at Duke University Medical Center from 2012 to 2014. A total of 152 TAVI patients with a median age of 81 years (median interquartile range 74 to 86) were included. TAVI resulted in the reduction of left ventricle (LV) mass index (g/m2), median (interquartile range) 130 (115 to 157) pre versus 106 (85 to 135) post, p <0.001; LV end-diastolic volume (ml) 127 (105 to 143) pre versus 120 (100 to 143) post, p = 0.013; and LV end-systolic volume (ml) 55 (38 to 77) pre versus 45 (40 to 65) post, p = 0.027. TAVI also significantly improved LV global longitudinal strain (%) −14.4 (−11.3, −15.5) pre versus −14.8 (−12.2, −16.6) post (p <0.001, respectively). Post-TAVI LV mass regression was predicted by baseline LV mass and LV global longitudinal strain whereas post-TAVI LV ejection fraction was predicted by baseline LV ejection fraction, LV mass, and post-TAVI paravalvular leak. In conclusion, TAVI results in significant cardiac hemodynamic, geometrical, and functional changes at approximately 1-year postprocedure for patients with AS. Better baseline myocardial structure and function leads to more reverse remodeling.

El texto completo de este artículo está disponible en PDF.

Esquema


 Funding Source: This study was funded by an investigator-initiated Boston Scientific-Duke Strategic Alliance for Research grant award to ZS.
Conflict of interest: None.


© 2018  Publicado por Elsevier Masson SAS.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 123 - N° 5

P. 813-819 - mars 2019 Regresar al número
Artículo precedente Artículo precedente
  • Comparison of the Kansas City Cardiomyopathy Questionnaire and Minnesota Living With Heart Failure Questionnaire in Predicting Heart Failure Outcomes
  • Derek Yee, Eric Novak, Anne Platts, Michael E. Nassif, Shane J. LaRue, Justin M. Vader
| Artículo siguiente Artículo siguiente
  • Meta-Analysis of Impact of Baseline N-TerminalPro-Brain Natriuretic Peptide Levels on SurvivalAfter Transcatheter Aortic Valve Implantation for Aortic Stenosis
  • Hisato Takagi, Yosuke Hari, Norikazu Kawai, Toshiki Kuno, Tomo Ando, for the ALICE (All-Literature Investigationof Cardiovascular Evidence) Group

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.