InSafeLock humeral nail provides a safe application for proximal and distal locking screws with distal endopin – An anatomical study - 27/08/19

Doi : 10.1016/j.otsr.2019.04.014 
Murat Tasci a, , İsmail Turkmen a, Haluk Celik a, Mehmet Akif Akcal b, Rahime Şekerci c, Nigar Keles c, Necdet Saglam a, Fuat Akpinar a
a Umraniye Training and Research Hospital, Orthopaedics and Traumatology, Istanbul, Turkey 
b Antalya Ataturk State Hospital, Orthopaedics and Traumatology, Antalya, Turkey 
c Akdeniz University, Anatomy, Antalya, Turkey 

Corresponding author. Atatürk mah. Guner sokak, Metropark Sitesi A2 Blok D10, Kuçukçekmece, Istanbul, Turkey.Atatürk mah. Guner sokakMetropark Sitesi A2 Blok D10KuçukçekmeceIstanbulTurkey

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Introduction

Efforts to prevent iatrogenic neurovascular injuries with humeral intramedullary nailing lead to design new implants and inside to out distal locking technique using an endopin aims to provide a safer screw application. InSafeLock (TST, Istanbul, Turkey) humeral nail have been recently developed to minimize the possible screw related complications. The anatomical relationship between locking screws and neurovascular structures with the application time were compared between Trigen Humeral Nail (Smith and Nephew, Memphis, USA) and InSafeLock Humeral Nail.

Hypothesis

InSafeLock humeral nail would be safer than Trigen Humeral nail in terms of neurovascular injury.

Materials and methods

Seven cadavers were used with both shoulders and surgical application of two nails was performed as the manufacturer guide. An Insafelock humeral nail was used for each right humerus and a Trigen humeral nail was used for each left humerus. Once the nails were placed, proximal and distal region of the nails were dissected to evaluate the relationship between screws and adjacent anatomical structures. The duration of the each screw was assessed via a stopwatch.

Results

No significant finding was noted for the relationship between the neurovascular structures and proximal screws in two groups (p<0.05). The distal locking of the InSafeLock humerus nail had a shorter application time and no neurovascular damage was recorded.

Discussion

The newly developed Insafelock humerus nails are at least as safe and effective as current humeral nails available on the market. Additional benefits include the preservation of neurovascular structures, as the Insafelock humerus nail does not require the use of an extra incision. Furthermore, surgical time is significantly shorter with using distal endopin.

Level of study

III, controlled laboratory study.

El texto completo de este artículo está disponible en PDF.

Keywords : Humerus diaphysis fracture, Intramedullary nail, Neurovascular damage


Esquema


© 2019  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 105 - N° 5

P. 1005-1011 - septembre 2019 Regresar al número
Artículo precedente Artículo precedente
  • Femoral neck shortening after internal fixation of Garden I fractures increases the risk of femoral head collapse
  • Léo Nanty, François Canovas, Thibaut Rodriguez, Patrick Faure, Louis Dagneaux
| Artículo siguiente Artículo siguiente
  • Does migration of osseointegrated implants for transfemoral amputees predict later revision? A prospective 2-year radiostereometric analysis with 5-years clinical follow-up
  • Rehne Lessmann Hansen, Bente Lomholt Langdahl, Peter Holmberg Jørgensen, Klaus Kjær Petersen, Kjeld Søballe, Maiken Stilling

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.