Suscribirse

Flexion gap stabilization by oversizing posterior condylar offset in deep-dished total knee replacement does not compromise flexion: A single-surgeon, retrospective, observational, mid-term series - 19/09/19

Doi : 10.1016/j.otsr.2019.04.008 
Philippe Massin a, , Edouard Lefevre b, Julien Serane b
a Clinique Hartmann, 26, boulevard Victor-Hugo, 92200 Neuilly-sur-Seine, France 
b Service de chirurgie orthopédique, hôpitaux universitaires Paris Nord Val-de-Seine, 100, boulevard du Général Leclerc, 92100 Clichy, France 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Introduction

In total knee replacement surgery, medio-lateral knee balancing is recognized as the key to achieving satisfactory functional results. But it may not be enough to stabilize the flexion gap using deep-dished implants. We achieved flexion gap balance by oversizing the femoral component, thus increasing the posterior condylar offset (PCO). The purpose of this study was to describe the applicability of this technique and to test whether it produced adverse effects on medium-term outcomes. We hypothesized that it would not compromise the results if used properly. We therefore asked: (1) at how many cases of flexion gap balance would require oversizing the femoral component; (2) if femoral components oversizing would modify the mid-term results as per forgotten joint score (FJS) scores and whether flexion gain would be comparable to patients in whom it was not increased.

Materials and methods

Ninety-four patients (120 knees) were operated between September 2009 and 2011 (age 68±9 years) using the cementless Hyperflex version of the Natural Knees (Zimmer, Warsaw, IN, USA). Postero stabilization was achieved using deep-dished inserts. The Gender configuration has provided narrow inserts to better adapt the female anatomy. A special navigation system measured the displacement of the lateral and medial femoro-tibial contact points with infra-millimetric precision. Adopting a tibial cut first, gap-balancing technique with anterior referencing, the decision to oversize the femoral component relied on the 90° flexion drawer test, which showed more than 6mm sagittal laxity before the femoral bone cuts. Eighty-one (105 knees) patients were reviewed with average 63±27-month follow-up.

Results

Femoral components were augmented by 1 size in 60 cases and by 2 sizes in 7 cases. At final review, knees with an oversized femoral component (60) achieved the same results as those implanted with a non-oversized femoral component (n=45) in terms of mean flexion gain (−5°±34 versus −4°±23, p=0.78), mean FJS (63±26 versus 61±23; p=0.56).

Conclusion

Balancing the Flexion gap by oversizing the femoral component did not compromise flexion range and functional results.

Level of evidence

IV, Retrospective cohort study.

El texto completo de este artículo está disponible en PDF.

Keywords : Deep-dished total knee replacement, Femoral component size, Sagittal balance, Navigation, Primary total knee replacement


Esquema


© 2019  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 105 - N° 6

P. 1039-1045 - octobre 2019 Regresar al número
Artículo precedente Artículo precedente
  • Where are we with return-to-sport testing following ACL reconstruction?
  • Julian A. Feller, Kate E. Webster
| Artículo siguiente Artículo siguiente
  • Same-stage total knee arthroplasty and osteotomy for osteoarthritis with extra-articular deformity. Part I: Tibial osteotomy, prospective study of 26 cases
  • Yves Catonné, Elhadi Sariali, Frédéric Khiami, Jean-Louis Rouvillain, Antony Wajsfisz, Hugues Pascal-Moussellard

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.