Suscribirse

Computer-aided diagnosis system for characterizing ISUP grade ? 2 prostate cancers at multiparametric MRI: A cross-vendor evaluation - 26/11/19

Doi : 10.1016/j.diii.2019.06.012 
S. Transin a, R. Souchon b, C. Gonindard-Melodelima c, R. de Rozario b, d, P. Walker e, f, M. Funes de la Vega g, R. Loffroy a, e, L. Cormier h, O. Rouvière b, i, j,
a Department of Radiology, University Hospital François-Mitterrand, 21000 Dijon, France 
b Inserm, U1032, LabTau, 69003 Lyon, France 
c CNRS, UMR 5553, Laboratoire d’Ecologie Alpine, Université Grenoble-Alpes, 38041 Grenoble, France 
d Département Informatique, Faculté des Sciences et Technologies, Université Lyon 1, 69000 Lyon, France 
e Medical Imaging Group, Laboratory of Electronics, Computer Science and Imaging (Le2I), CNRS 6306, University of Burgundy, 21000 Dijon, France 
f Department of MR Spectroscopy, University Hospital François-Mitterrand, 21000 Dijon, France 
g Department of Pathology, University Hospital François-Mitterrand, 21000 Dijon, France 
h Department of Urology, University Hospital François-Mitterrand, 21000 Dijon, France 
i Department of Urinary and Vascular Radiology, Hôpital Édouard-Herriot, Hospices Civils de Lyon, 69437 Lyon, France 
j Université de Lyon, Université Lyon 1, faculté de médecine Lyon Est, Lyon, France 

Corresponding author at: Service d’imagerie, pavillon B, hôpital Edouard-Herriot, 5, place d’Arsonval, 69437 Lyon, France.Service d’imagerie, pavillon B, hôpital Edouard-Herriot5, place d’ArsonvalLyon69437France

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Purpose

To assess the performance of a computer-aided diagnosis (CADx) system trained at characterizing International Society of Urological Pathology (ISUP) grade2 peripheral zone (PZ) prostate cancers on multiparametric magnetic resonance imaging (mpMRI) examinations from a different institution and acquired on different scanners than those used for the training database.

Patients and methods

Preoperative mpMRIs of 74 men (median age, 65.7 years) treated by prostatectomy between 2014 and 2017 were retrospectively selected. One radiologist outlined suspicious lesions and scored them using Prostate Imaging-Reporting and Data System version 2 (PI-RADSv2); their CADx score was calculated using a classifier trained on an independent database of 106 patients treated by prostatectomy in another institution. The lesions’ nature was assessed by comparison with prostatectomy whole-mounts. Diagnostic accuracy was estimated with areas under receiver operating characteristic curves (AUCs). Sensitivity and specificity were calculated using a CADx threshold (≥0.21) that yielded 95% sensitivity in the training database, and a PI-RADSv23 threshold.

Results

A total of 127 lesions (PZ, n=104; transition zone [TZ], n=23) were described. In PZ, CADx and PI-RADSv2 scores had similar AUCs for characterizing ISUP grade2 cancers (0.78 [95% confidence interval (CI): 0.69–0.87] vs. 0.74 [95%CI: 0.62–0.82], respectively) (P=0.59). Sensitivity and specificity were respectively 89% (95%CI: 82–97%) and 42% (95%CI: 26–58%) for the CADx score, and 97% (95%CI: 93–100%) and 37% (95%CI: 22–52%) for the PI-RADSv2 score. In TZ, both scores showed poor specificity.

Conclusion

In this external cohort, the CADx and PI-RADSv2 scores showed similar performances in characterizing ISUP grade2 cancers.

El texto completo de este artículo está disponible en PDF.

Keywords : Male, Prostatic neoplasms, Magnetic resonance imaging (MRI), Diagnosis, Computer-assisted diagnosis


Esquema


© 2019  Société française de radiologie. Publicado por Elsevier Masson SAS. Todos los derechos reservados.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 100 - N° 12

P. 801-811 - décembre 2019 Regresar al número
Artículo precedente Artículo precedente
  • Percutaneous transhepatic Laser lithotripsy for intrahepatic cholelithiasis
  • A. Lamanna, J. Maingard, J. Tai, D. Ranatunga, M. Goodwin
| Artículo siguiente Artículo siguiente
  • Preclinical evaluation of the atraumatic nature of a spring loaded blunt tip coaxial needle in a swine model
  • P.P. Rao, E. Breton, J. Garnon, R.L. Cazzato, G. Koch, J. Caudrelier, G. Tsoumakidou, A. Gangi

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.