Suscribirse

Split-hand phenomenon quantified by the motor unit number index for distinguishing cervical spondylotic amyotrophy from amyotrophic lateral sclerosis - 30/11/19

Doi : 10.1016/j.neucli.2019.09.001 
Chaojun Zheng a, 1, Yu Zhu b, Minghao Shao a, Dongqing Zhu c, 1, Hong Hu d, 1, Kai Qiao c, Jianyuan Jiang a,
a Department of Orthopedics, Huashan Hospital, Fudan University, 200040 Shanghai, China 
b Department of Physical Medicine and Rehabilitation, Upstate Medical University, State University of New York at Syracuse, 10212 Syracuse, NY, USA 
c Department of Neurology, Huashan Hospital, Fudan University, 200040 Shanghai, China 
d Department of Emergency, Huashan Hospital, Fudan University, 200040 Shanghai, China 

Corresponding author at: Department of Orthopedics, Huashan Hospital, Fudan University, 12, Mid-Wulumuqi Road, 200040 Shanghai, China.Department of Orthopedics, Huashan Hospital, Fudan University12, Mid-Wulumuqi RoadShanghai200040China

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

páginas 14
Iconografías 9
Vídeos 0
Otros 0

Summary

Objectives

To investigate and compare split-hand phenomenon quantified by motor unit number index (MUNIX) between patients with cervical spondylotic amyotrophy (CSA) and those with amyotrophic lateral sclerosis (ALS).

Methods

MUNIX was performed on abductor pollicis brevis (APB), abductor digiti minimi (ADM) and first dorsal interosseous (FDI) in 46 CSA patients, 39 ALS patients and 41 healthy subjects. Split-hand measurements including split-hand index (SHI=ABP×FDI/ADM), ratio of APB to ADM (AA), ratio of FDI to ADM (FA) were measured by compound muscle action potential (CMAP) and MUNIX.

Results

There was a significant difference in both AA and SHI measured by two different methods between ALS and CSA patients (P<0.05). Receiver operating characteristic (ROC) curve and logistic regression analysis demonstrated good differential diagnostic accuracy for AA, SHI and their combination between ALS and CSA. A larger area under the curve (AUC) was observed in these measurements calculated by MUNIX than those measured by CMAP (AA: 0.885 vs. 0.700, SHI: 0.865 vs. 0.703, Combination: 0.925 vs. 0.750; P<0.05). Sub-group analysis of ROC curves revealed an AUC of 0.893 for AAMUNIX, 0.801 for SHIMUNIX and 0.896 for their combination in differentiating “clinically possible” ALS (Awaji-Shima criteria) from CSA (P<0.05).

Conclusions

Both AA and SHI measured by two different methods are useful in distinguishing ALS from CSA, and those quantified by MUNIX may be a better differential diagnostic marker to provide an accurate and noninvasive additional test for distinguishing CSA from ALS, even in their early stages.

El texto completo de este artículo está disponible en PDF.

Keywords : Cervical spondylotic amyotrophy, Amyotrophic lateral sclerosis, Split-hand phenomenon, Motor unit number index, Differential diagnosis


Esquema


© 2019  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 49 - N° 5

P. 391-404 - novembre 2019 Regresar al número
Artículo precedente Artículo precedente
  • Modulation of sensory nerve fiber excitability by transcutaneous cathodal direct current stimulation
  • André Caetano, Pedro Pereira, Mariana Pereira, Mamede de Carvalho

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
La compra de artículos no está disponible en este momento.

¿Ya suscrito a @@106933@@ revista ?

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.