Suscribirse

Clinical evaluation of double-plate osteosynthesis for olecranon fractures: A retrospective case-control study - 05/12/19

Doi : 10.1016/j.otsr.2019.08.019 
Alexander Ellwein a, b, , Konstantinos Argiropoulos b, Rony-Orijit DeyHazra b, Marc-Frederic Pastor a, Tomas Smith a, Helmut Lill b
a Department for Orthopaedic Surgery, Medical School Hannover, DIAKOVERE Annastift, Anna-von-Borries-Straße 1-7, 30625 Hannover, Germany 
b Department for Orthopaedic Surgery and Traumatology, DIAKOVERE Friederikenstift, Humboldtstr 5, 30169 Hannover, Germany 

Corresponding author at: Department for Orthopaedic Surgery, Medical School Hannover, DIAKOVERE Annastift, Anna-von-Borries-Straße 1-7, 30625 Hannover, Germany.Department for Orthopaedic Surgery, Medical School Hannover, DIAKOVERE AnnastiftAnna-von-Borries-Straße 1-7Hannover30625Germany

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Introduction

Single, dorsal plating is a commonly used technique for treating olecranon fractures. Double-plate osteosynthesis is an alternative treatment. Aim of this study was to present the surgical technique using this novel double-plate implant for olecranon fractures and review clinical results, complication rates and revision surgeries. Results were compared to single, dorsal plating.

Hypothesis

Does double-plate osteosynthesis for olecranon fractures improve material's tolerance with respect to osteosynthesis by single dorsal plating?

Patients and methods

Between February 2011 and March 2015, we retrospectively evaluated 47 patients who were included in this study: 25 were treated with a low-profile double-plate osteosynthesis and 22 with an anatomically pre-shaped 3.5mm locking compression plate (LCP). The 2 groups were the result of a change of implants in our department in 2013. Patient satisfaction, range of motion, patient related outcome scores (Mayo Elbow Performance Score [MEPS], Disabilities of Arm, Shoulder and Hand Score [DASH]), complications and revision surgeries were evaluated. Results between both implant types were statistically compared using the Mann-Whitney U test.

Results

After a mean follow-up of 41 months (range: 25–61), the low-profile double-plate group showed a range of motion of 127°, MEPS of 94 and DASH of 6. The 3.5mm LCP group was found to have a range of motion of 130°, MEPS of 96 and DASH of 8. No clinical difference was found between groups. A total of 9 revision surgeries after double-plate osteosynthesis were recorded including seven implant removals and two intraarticular screws. One loosening of a screw without revision surgery was reported. The 3.5mm LCP group had 9 revision surgeries including eight implant removals and one intraarticular screw.

Discussion

Low-profile double-plate osteosynthesis is a safe and effective alternative treatment of olecranon fractures. Subjective and objective clinical outcome measures revealed a low complication rate and excellent results. Still, implant removal due to soft tissue irritation remains an issue. These findings were comparable to common dorsal plate osteosynthesis.

Level of evidence

III, retrospective case-control study.

El texto completo de este artículo está disponible en PDF.

Keywords : Olecranon fracture, Double-plate osteosynthesis, Low-profile, LCP, Complication


Esquema


© 2019  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 105 - N° 8

P. 1601-1606 - décembre 2019 Regresar al número
Artículo precedente Artículo precedente
  • Advantages of expulsion-proof pins in the treatment of olecranon fractures with tension band wiring: Comparison with a control group
  • Rémi Di Francia, Hoel Letissier, Dominique Le Nen, Christian Lefèvre, Frédéric Dubrana, Éric Stindel
| Artículo siguiente Artículo siguiente
  • Total wrist denervation: Retrospective study of 39 wrists with 56 months’ follow-up
  • Baptiste Picart, Clément Laborie, Christophe Hulet, Mélanie Malherbe

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.