Abstract

Femoral stem modularity in hip replacement was first developed to connect a ceramic head to the stem, then extended to metal heads using the Morse taper principle. Is it a good thing, or a necessary evil? It contributes to improving lower limb length and lateralization setting, at the cost of fairly rare complications such as dissociation and fretting corrosion, which can exceptionally lead to ARMD (Adverse Reaction to Metal Debris). Modular necks were later recommended, with a double Morse taper: cylindrical for the head junction, and more or less flattened for the stem. Is this one modularity too far? Dual modularity in theory perfectly reproduces the biomechanical parameters of the hip, but is unfortunately associated with fractures and severe corrosion, leading to ARMD and pseudotumor, especially in Cr-Co necks. Moreover, it provides no functional advantage, and no longer has a role outside dysplasia and other femoral deformities. Metaphyseal-diaphyseal modularity is not widespread in primary implants, and is it really necessary? Only one model has been widely studied: S–Rom™ (Depuy®). It features a metaphyseal sleeve adapting to the anatomy of the proximal femur, with a stem fitted via an inverse Morse taper. Its only interest is in case of congenital dislocation; like all metal connections, it incurs a risk of fracture and corrosion. On the other hand, modularity is widely employed in revision implants. Does it really help these procedures? The connection between a proximal femoral component of variable geometry and a diaphyseal stem with press-fit distal fixation provides a real solution to problems of length, lateralization and anteversion. Early models encountered high rates of fracture, but current implants and rigorous surgical technique have reduced this risk. Corrosion is a less serious problem, as the Morse taper undergoes only axial stress, without the friction undergone by other models subject to varus stress.

El texto completo de este artículo está disponible en PDF.

Keywords : Total hip replacement, Femoral revision, Modularity, Modular neck, Modular femoral stem


Esquema


© 2019  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 106 - N° 1S

P. S35-S42 - février 2020 Regresar al número
Artículo precedente Artículo precedente
  • Specificities of total hip and knee arthroplasty revision for infection
  • Jean-Yves Jenny
| Artículo siguiente Artículo siguiente
  • Tendon transfers in rotator-cuff surgery
  • Jean Kany

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.