Suscribirse

Embolization using hydrogel-coated coils for pulmonary arteriovenous malformations - 27/02/20

Doi : 10.1016/j.diii.2019.10.008 
T. Iguchi a, , T. Hiraki a, Y. Matsui a, H. Fujiwara b, J. Sakurai c, K. Baba d, S. Toyooka e, H. Gobara a, S. Kanazawa a
a Department of Radiology, Okayama University Medical School, 2-5-1 Shikata-cho kita-ku, Okayama 700-8558, Japan 
b Department of Radiology, Okayama City Hospital, Okayama 700-8557, Japan 
c Center for Innovative Clinical Medicine, Okayama University Hospital, Okayama 700-8558, Japan 
d Interventional Radiology Center, Okayama University Hospital, Okayama 700-8558, Japan 
e Department of General Thoracic Surgery, Okayama University Medical School, Okayama 700-8558, Japan 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Purpose

To prospectively evaluate the efficacy and safety of embolization using hydrogel-coated coils for the treatment of pulmonary arteriovenous malformations (PAVMs).

Materials and methods

The outcomes of 21 PAVMs in 19 patients (3 men and 16 women; mean age, 58.8±15.2 [SD] years; age range 14–78 years) treated by venous sac embolization (VSE) with additional feeding artery embolization were prospectively evaluated. For VSE, using one or more 0.018-inch hydrogel-coated coils was mandatory. Recanalization and/or reperfusion were evaluated by pulmonary arteriography 1 year after embolization.

Results

The mean feeding artery and venous sac sizes were 4.0mm and 8.5mm, respectively. Embolization was successfully completed in 20/21 PAVMs, yielding a technical success rate of 95%. The feeding artery was also embolized in 17/20 successful PAVMs (85%). A technical failure occurred in one PAVM, where embolization was abandoned because of migration of one bare coil to the left ventricle. The mean numbers of hydrogel-coated coils and bare platinum detachable coils used for VSE were 3.3±2.1 (SD) (range, 1–8) and 4.4±3.9 (SD) (range, 1–17), respectively. The mean percentages of hydrogel-coated coils in number, length, and estimated volume were 42.9%, 33.3%, and 72.7% respectively. One patient with one PAVM was lost to follow-up after 3 months. Neither recanalization nor reperfusion was noted in the remaining 19 PAVMs (success rate, 19/19 [100%]). One grade 4 (coil migration) adverse event occurred, and it was treated without any sequelae.

Conclusion

VSE using hydrogel-coated coils with additional feeding artery embolization is a safe and effective treatment for PAVM.

El texto completo de este artículo está disponible en PDF.

Keywords : Pulmonary arteriovenous fistulas, Lung, Arteriovenous malformation, Embolization


Esquema


© 2019  Société française de radiologie. Publicado por Elsevier Masson SAS. Todos los derechos reservados.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 101 - N° 3

P. 129-135 - mars 2020 Regresar al número
Artículo precedente Artículo precedente
  • Differentiating benign and malignant adnexal masses: Work still in progres
  • A. Tong
| Artículo siguiente Artículo siguiente
  • Assessment of ventricular tachyarrhythmia in patients with hypertrophic cardiomyopathy with machine learning-based texture analysis of late gadolinium enhancement cardiac MRI
  • D. Alis, A. Guler, M. Yergin, O. Asmakutlu

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.