Suscribirse

Differentiation between benign and malignant ovarian masses using multiparametric MRI - 27/02/20

Doi : 10.1016/j.diii.2020.01.006 
S. Türkoğlu a, , M. Kayan b
a Department of Radiology, Denizli State Hospital, 20010 Denizli, Turkey 
b Department of Radiology, School of Medicine, Suleyman Demirel University, 32260 Isparta, Turkey 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Purpose

To investigate the capabilities of multiparametric MRI including dynamic contrast enhanced (DCE) perfusion and diffusion-weighted imaging (DWI) to discriminate between benign and malignant ovarian masses.

Methods

A total of 43 women with a total of 43 ovarian masses were retrospectively included. They had a mean age of 51.26±18.05 (SD) years (range: 20–88years). Twenty women had benign and 23 had malignant ovarian tumors. All women had multiparametric MRI examinations including DWI (b50-b800) and DCE perfusion imaging at 1–5T. Results of DWI (apparent diffusion coefficient [ADC], b-800) and DCE imaging (volume transfer coefficient [Ktrans], rate constant [Kep], interstitial volume [Ve], initial area under the curve [iAUC]) were compared between benign and malignant ovarian masses.

Results

Mean ADC was significantly lowed in malignant tumors (0.92±0.25 [SD]×10−3 mm2/s (range: 0.6–1.6×10−3 mm2/s) than in benign tumors (1.37±0.69 [SD]×10−3 mm2/s; range: 0.4–2.9×10−3 mm2/s) (P=0.011). B-800 was significantly greater in malignant tumors (80.61±24.73 [SD] s/mm2; range: 24–110 s/mm2) than in benign ones (61.15±22.17 [SD] s/mm2; range: 38–155 s/mm2) (P=0.010). Ktrans was lower in benign tumors (0.13±0.06 [SD] min−1; range: 0–0.2min−1) than in malignant ones (0.25±0.16 [SD] min−1; range: 0.1–0.8min−1) (P=0.002). Kep was significantly greater in malignant tumors (0.55±0.19 [SD] min−1; range: 0.1–1.9min−1) than in benign ones (0.44±0.38 [SD] min−1; range: 0.2–1.1min−1) (P=0.003). iAUC was greater in malignant tumors (15.59±7.98 [SD] mM/min; range: 6.6–42.1mM/min) than in benign ones (7.98±5.06 [SD] mM/min; range: 0.2–17.7mM/min) (P=0.001). No differences in Ve were found between benign and malignant masses (P=0.084). The area under the ROC curve was significant for all parameters but Ve. Logistic regression analysis revealed 5.590 and 11.637 times higher malignancy risk for an ADC0.93×10−3 mm2/s and an iAUC13.88mM/min, respectively.

Conclusion

Multiparametric MRI has high accuracy in discrimination between benign and malignant ovarian masses. Therefore, adding these methods to the more common MRI protocol can help select the best treatment option in women with ovarian mass.

El texto completo de este artículo está disponible en PDF.

Keywords : Multiparametric magnetic resonance imaging, Apparent diffusion coefficient (ADC), Dynamic contrast enhancement (DCE) perfusion, Logistic models, Ovarian neoplasms


Esquema


© 2020  Société française de radiologie. Publicado por Elsevier Masson SAS. Todos los derechos reservados.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 101 - N° 3

P. 147-155 - mars 2020 Regresar al número
Artículo precedente Artículo precedente
  • Assessment of ventricular tachyarrhythmia in patients with hypertrophic cardiomyopathy with machine learning-based texture analysis of late gadolinium enhancement cardiac MRI
  • D. Alis, A. Guler, M. Yergin, O. Asmakutlu
| Artículo siguiente Artículo siguiente
  • Positron emission tomography/computed tomography guided percutaneous biopsies of Ga-68 avid lesions using an automated robotic arm
  • R. Kumar, B.R. Mittal, A. Bhattacharya, S.K. Vadi, H. Singh, A. Bal, J. Shukla, H. Singh, V. Sharma, A. Sood, S.K. Singh

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.