Suscribirse

Anterior approach without traction table: A means of saving time and money in hemiarthroplasty for femoral neck fracture? A case-matched study with and without traction table - 25/04/20

Doi : 10.1016/j.otsr.2020.01.009 
Elliott Kierszbaum , David Biau, Aymane Moslemi, Jules Descamps, Philippe Anract, Alexandre Hardy
 Service de Chirurgie Orthopédique et Traumatologique, CHU Cochin, 27, rue du Faubourg Saint-Jacques, 75014 Paris, France 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Background

The costs incurred by management of displaced femoral neck fracture are a public health issue. The anterior approach can be used for partial hip replacement, but costs in terms of equipment and time incurred by using a traction table have not to our knowledge been estimated in this indication. We therefore performed a case-control study, comparing (1) installation and deinstallation times (IT, DT) in partial hip replacement using a standard versus a traction table (ST, TT), and (2) operating times, limb-length radiography and intraoperative complications.

Hypothesis

Performing the anterior approach on a standard table saves installation and deinstallation time and operating time, without leading to more intraoperative complications.

Materials and methods

A comparative retrospective study included 102 patients (mean age, 84.8±8 years; 46 ST, 56 TT). Installation time (IT) was calculated between entry in the operating room and performance of the incision; operating time (OT) between incision and closure; and deinstallation time (DT) between closure and leaving the operating room.

Results

Mean IT in ST (25.5±6.2min) was significantly shorter than in TT (33.9±6.2min) (p=1.1*10−9), as were DT (13±4.7 versus 17±3.4min) (p=4.1*10−6) and OT (73.5±15.9 versus 82.6±21.3minutes) (p=0.01). There were 4 intraoperative complications: 1 greater trochanter fracture in ST and 2 greater trochanter fractures and 1 proximal femoral fracture in TT. Limb-length discrepancy was comparable between ST (3.7±3.2mm (range, 0-15mm)) and TT (5.3±4.6mm (range, 0-20mm)) (p=0.06).

Discussion

Patient installation on a standard table reduced installation, deinstallation and operating time compared to use of a traction table, without increasing the complications rate.

Level of evidence

III, case-control study.

El texto completo de este artículo está disponible en PDF.

Keywords : Hip replacement, Femoral neck fracture, Anterior approach, Time, Installation, Standard table

Abbreviations : IT, DT, OT, ST, TT


Esquema


© 2020  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 106 - N° 3

P. 583-588 - mai 2020 Regresar al número
Artículo precedente Artículo precedente
  • One-stage bilateral total hip arthroplasty versus unilateral total hip arthroplasty: A retrospective case-matched study
  • Grégoire Micicoi, Régis Bernard de Dompsure, Lolita Micicoi, Laurie Tran, Michel Carles, Pascal Boileau, Christophe Trojani
| Artículo siguiente Artículo siguiente
  • Stemmed acetabular cup as a salvage implant for revision total hip arthroplasty with Paprosky type IIIA and IIIB acetabular bone loss
  • Samir-Pierre Issa, David Biau, Philippe Leclerc, Antoine Babinet, Moussa Hamadouche, Philippe Anract

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.