Suscribirse

Prospective assessment of reproducibility of three-dimensional ultrasound for fetal biometry - 29/07/20

Doi : 10.1016/j.diii.2020.03.004 
G. Ambroise Grandjean a, b, c, , P. Berveiller d, e, G. Hossu f, P. Noble g, M. Chamagne b, O. Morel a, b
a Inserm, IADI, Université de Lorraine, 54000 Nancy, France 
b Department of Obstetrics and Gynecology, Centre hospitalier regional universitaire de Nancy, 54000 Nancy, France 
c Midwifery Department, Université de Lorraine, 54000 Nancy, France 
d Department of Obstetrics and Gynecology, Centre hospitalier intercommunal de Poissy Saint-Germain-en-Laye, 78300 Poissy, France 
e Université Versailles-Saint-Quentin, 78180 Montigny-le-Bretonneux, France 
f CIC-IT, Centre hospitalier regional universitaire de Nancy, 54000 Nancy, France 
g Department of Obstetrics and Gynecology, Port-Royal, hôpital Cochin, Assistance Publique–Hôpitaux de Paris, 75014 Paris, France 

Corresponding author at: Inserm, IADI, Université de Lorraine, 54000 Nancy, France.Inserm, IADI, Université de LorraineNancy54000France

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Highlights

Standardized measurements of fetal biometry can be performed using 3D ultrasound.
Repeatability and reproducibility of junior observer are more in line with those of senior observer when 3D ultrasound is used to perform fetal biometry.
Due to the volume-processing step, the 3D technique is significantly slower overall but allows for significant reduction in the “point of care” examination for the junior observer.

El texto completo de este artículo está disponible en PDF.

Abstract

Purpose

To compare fetal ultrasound measurements performed by two observers with different levels of experience and evaluate the potential contribution of the use of three-dimensional (3D) ultrasound on repeatability, reproducibility and agreement of two-dimensional (2D) and 3D-derived measurements.

Materials and methods

Two observers (one senior and one junior) measured head circumference (HC), abdominal circumference (AC) and femur length (FL) in 33 fetuses (20 to 40 weeks of gestation). Each observer performed two series of 2D measurements and two series of 3D measurements (i.e., measurements derived from triplane volume processing). Measurements were converted into Z-scores according to gestational age. Variability between the different series of measurements was studied using Bland–Altmann plots and intra-class correlation coefficients (ICC).

Results

Agreement with the 2D measurements of the senior observer was higher in 3D than in 2D for the junior observer (systematic differences of −0.4, −0.2 and −0.8 Z-score vs. −0.1, −0.1 and −0.6 for HC, AC and FL on 2D and 3D datasets, respectively). The use of 3D ultrasound improved junior observer repeatability (ICC=0.94, 0.88, 0.90 vs. 0.94, 0.94 and 0.96 for HC, AC and FL in 2D and 3D, respectively). The reproducibility was greater using the junior observer 3D datasets (ICC=0.75, 0.60 and 0.45 vs. 0.79, 0.89 and 0.63 for HC, AC and FL, respectively).

Conclusion

The use of 3D ultrasound improves the consistency of the measurements performed by a junior observer and increases the overall repeatability and reproducibility of measurements performed by observers with different levels of experience.

El texto completo de este artículo está disponible en PDF.

Keywords : Gestational age, Reproducibility of results, Ultrasonography, Three-dimensional ultrasound

Abbreviations : 2D, 3D, AC, BMI, CI, EFW, FL, HC, HSD, ICC, WG


Esquema


© 2020  Société française de radiologie. Publicado por Elsevier Masson SAS. Todos los derechos reservados.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 101 - N° 7-8

P. 481-487 - juillet 2020 Regresar al número
Artículo precedente Artículo precedente
  • Impact of ultra-low dose CT acquisition on semi-automated RECIST tool in the evaluation of malignant focal liver lesions
  • A. Hamard, J. Frandon, A. Larbi, J. Goupil, H. De Forges, J.-P. Beregi, J. Greffier
| Artículo siguiente Artículo siguiente
  • Evaluation of an acetated Ringer-based contrast material mixture for postmortem computed tomography angiography
  • A.R.J. Péporté, D. Gascho, S. Stamou, S. Bensler, M.J. Thali, S. Leschka, P.M. Flach

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.