Suscribirse

Intraoperative pulmonary hyperdistention estimated by transthoracic lung ultrasound: A pilot study - 09/12/20

Doi : 10.1016/j.accpm.2020.09.009 
Bruno Tonelotto a, , Sérgio Martins Pereira b, Mauro Roberto Tucci c, Diogo Florenzano Vaz a, Joaquim Edson Vieira b, Luiz Marcelo Malbouisson b, Frédérick Gay d, Claudia Marquez Simões b, Maria José Carvalho Carmona b, Antoine Monsel e, Marcelo Brito Amato c, Jean-Jacques Rouby e, José Otavio Costa Auler b
a Divisão de Anestesiologia, Hospital Sírio-Libanês, Dona Adma Jafet Street, 91, São Paulo 1308050, Brazil 
b Divisão de Anestesiologia do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, Av Doutor Eneas de Carvalho Aguiar, 255, São Paulo 0540300, Brazil 
c Divisão de Pneumologia do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, Av Doutor Eneas de Carvalho Aguiar, 255, São Paulo 0540300, Brazil 
d Department of Parasitology-Mycology, La Pitié-Salpêtrière hospital, Assistance Publique Hôpitaux de Paris, Sorbonne University of Paris, 47, Boulevard de l’Hôpital, 75013 Paris, France 
e Multidisciplinary Intensive Care Unit, Department of Anesthesiology and Critical Care Medicine, La Pitié-Salpêtrière hospital, Assistance Publique Hôpitaux de Paris, Sorbonne University of Paris, 47, Boulevard de l’Hôpital, 75013 Paris, France 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

páginas 7
Iconografías 5
Vídeos 0
Otros 0

Abstract

Introduction

Transthoracic lung ultrasound can assess atelectasis reversal and is considered as unable to detect associated hyperdistention. In this study, we describe an ultrasound pattern highly suggestive of pulmonary hyperdistention.

Methods

Eighteen patients with normal lungs undergoing lower abdominal surgery were studied. Electrical impedance tomography was calibrated, followed by anaesthetic induction, intubation and mechanical ventilation. To reverse posterior atelectasis, a recruitment manoeuvre was performed. Positive-end expiratory pressure (PEEP) titration was then obtained during a descending trial – 20, 18, 16, 14, 12, 10, 8, 6 and 4cmH2O. Ultrasound and electrical impedance tomography data were collected at each PEEP level and interpreted by two independent observers. Spearman correlation test and receiving operating characteristic curve were used to compare lung ultrasound and electrical impedance tomography data.

Results

The number of horizontal A lines increased linearly with PEEP: from 3 (0, 5) at PEEP 4cmH2O to 10 (8, 13) at PEEP 20cmH2O. The increase number of A lines was associated with a parallel and significant decrease in intercostal space thickness (p=0.001). The lung ultrasound threshold for detecting pulmonary hyperdistention was defined as the number of A lines counted at the PEEP preceding the PEEP providing the best respiratory compliance. Six A lines was the median threshold for detecting pulmonary hyperdistention. The area under the receiving operating characteristic curve was 0.947.

Conclusions

Intraoperative transthoracic lung ultrasound can detect lung hyperdistention during a PEEP descending trial. Six or more A lines detected in normally aerated regions can be considered as indicating lung hyperdistention.

Trial registration: NCT02314845 Registered on ClinicalTrials.gov.

El texto completo de este artículo está disponible en PDF.

Abbreviations : PEEP, CT, EIT, LU, BMI, ROC, ICC

Keywords : Positive end-expiratory pressure, Recruitment manoeuvre, Lung ultrasound, Pulmonary hyperdistention, A lines, Impedance tomography


Esquema


© 2020  Société française d'anesthésie et de réanimation (Sfar). Publicado por Elsevier Masson SAS. Todos los derechos reservados.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 39 - N° 6

P. 825-831 - décembre 2020 Regresar al número
Artículo precedente Artículo precedente
  • Atelectasis prevention during anaesthesia using high-flow nasal cannula therapy: A paediatric randomised trial using MRI images
  • César Roncin, Ugo Scemama, Laurent Zieleskiewicz, Anderson Loundou, Nathalie Lesavre, Renaud Vialet
| Artículo siguiente Artículo siguiente
  • Cervical arterial abnormalities and outcome after aneurysmal subarachnoid haemorrhage: A pilot cohort study
  • Clement Gakuba, Jean-Luc Hanouz, Charlotte Abadie, Thomas Gaberel, Florent Braud, Patrick Courthéoux, Emmanuel Touzé, Paul-Emile Labeyrie

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
La compra de artículos no está disponible en este momento.

¿Ya suscrito a @@106933@@ revista ?

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.