Suscribirse

Correlation between ejection dynamic parameters and usual echocardiographic methods for assessing aortic stenosis: A prospective study - 09/01/21

Doi : 10.1016/j.acvdsp.2020.10.073 
S. Serbout , A. Eladaoui, A. Ech-Chenbouli, S. Arous, L. Azzouzi, R. Habbal
 Cardiologie, CHU Ibn-Rochd, Casablanca, Morocco 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Resumen

Introduction

Aortic stenosis (AS) was the most frequent valve disease referred for surgical treatment in developed countries. The management of the disease depends of AS severity. Echocardiography is the mainstay of assessment, and three parameters are recommended for AS severity evaluation: effective orifice area, mean aortic gradient, and peak jet velocity.

Objective

Our study was to evaluate acceleration time (AT) and the ratio the AT/ET (ejection time) ratio as diagnostic parameters in AS and to analyse the defining characteristics of the aortic waveform.

Material and methods

Patients with AS were prospectively enrolled. Quantitative echocardiographic Doppler parameters including ejection dynamics (AT, ET, and AT/ET ratio) as well as conventional and clinical parameters were analysed. AT, ET, and AT/ET ratio were calculated in different stages of AS.

Results

Fifty-one patients were included (mean age, 56 years; 54% women), of whom 37 (74%) had severe AS and 14 (26%) patients had moderate AS; AT was higher in patients with higher levels of severity (121 vs. 85 msec, P<0.001), as well as AT/ET ratios (28% vs. 37%, P<0.001) (Table 1). Using a cut-off of 80 msec for AT and 32% for AT/TE, while there were no differences in ET (297 vs. 300ms, P=0.66). Receiver operating characteristic analysis showed that AT and AT/ET ratio could discriminate severe AS, whereas ET could not. We found good correlations between both ejection parameters (AT and AT/ET ratio) and all the usual echocardiographic methods for assessing AS (Fig. 1).

Conclusion

The present study shows that systolic time intervals, particularly AT and AT/ET ratio, are easy and accurate methods that are related to AS severity and could be used as alternatives in the echocardiographic assessment of this disease.

El texto completo de este artículo está disponible en PDF.

Esquema


© 2020  Publicado por Elsevier Masson SAS.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 13 - N° 1

P. 65-66 - janvier 2021 Regresar al número
Artículo precedente Artículo precedente
  • Poster: Cardiovascular magnetic resonance analysis for discrimination between hypertensive heart disease and hypertrophic cardiomyopathy
  • T. Filali, F. Walylo
| Artículo siguiente Artículo siguiente
  • Echocardiography in COVID-19 patients and its impact on treatment change
  • N. Benyounes, C. Van Der Vynckt, T. Tibi

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.