Abstract

Background

Precise implant alignment is a crucial prognostic factor for successful outcomes following total hip arthroplasty (THA). A portable accelerometer-based navigation (PN) device may achieve the same accuracy as that achieved by the computer-assisted navigation surgery technique, with the convenience of a conventional technique. Although the usefulness of PN in THA (PN-THA) has been reported, whether it is more accurate than performing THA with a conventional technique (CON-THA) remains controversial. The difference in surgical time between PN-THA and CON-THA is also unclear. Therefore, we conducted a systematic review and meta-analysis of studies comparing results of PN-THA with those of CON-THA. We focused on the following question: is PN-THA superior to CON-THA in terms of radiological parameters and surgical time?

Patients and Methods

A literature search was conducted in PubMed, Web of Science, and Cochrane Library, to identify studies that met the following inclusion criteria: randomised controlled trials (RCT) or non-RCT, studies involving patients who underwent PN-THA and patients who underwent CON-THA, studies including data on radiological parameters and surgical outcomes. Author names, publication year, country, study design, surgical approach, demographic characteristics of the participants (diagnosis, gender, age, and body mass index), and surgical outcomes (the radiological parameters and the surgical time) were extracted. We calculated the mean differences (MDs) for continuous data with 95% confidence intervals (CIs) for each outcome. p<0.05 was considered significant.

Results

Three studies were included in this meta-analysis. The meta-analysis showed that absolute deviation of the postoperative measured angles from the target position for the cup anteversion was significantly smaller in PN-THA than in CON-THA (MD=−1.70, 95% CI=−2.91 to −0.50, [p=0.005]). There was no significant difference in the absolute deviation of the postoperative measured angles from the target position for cup abduction between the groups (MD=−1.82, 95% CI=−4.32–0.67, [p=0.15]). The surgical time was significantly longer in PN-THA than in CON-THA (MD=8.58, 95% CI=4.05–13.10, [p=0.0002]).

Discussion

This systematic review and meta-analysis of studies comparing the results of PN-THA with those of CON-THA showed that the PN-THA is advantageous for precise cup implantation compared to CON-THA, although PN-THA has a longer surgical time compared to CON-THA.

Level of evidence

III.

El texto completo de este artículo está disponible en PDF.

Keywords : Total hip arthroplasty, Portable, Hand-held, Navigation, Systematic review, Meta-analysis

Abbreviations : PN, CON, MD, RCT, CAS


Esquema


© 2020  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 107 - N° 1

Artículo 102742- février 2021 Regresar al número
Artículo precedente Artículo precedente
  • Cementless hip revision cup for the primary fixation of osteoporotic acetabular fractures in geriatric patients
  • Christopher A. Becker, Christoph Linhart, Jan Bruder, Christian Zeckey, Axel Greiner, Adrian Cavalcanti Kußmaul, Simon Weidert, Eduardo M. Suero, Wolfgang Böcker, Christian Kammerlander
| Artículo siguiente Artículo siguiente
  • Symptomatic leg length discrepancy after total hip arthroplasty is associated with new onset of lower back pain
  • Felix W.A. Waibel, Kersten Berndt, Thorsten Jentzsch, Jan Farei-Campagna, Stefan Rahm, Claudio Dora, Patrick O. Zingg

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2025 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.