Suscribirse

Single versus splinted short implants at sinus augmented sites: A systematic review and meta-analysis - 21/05/21

Doi : 10.1016/j.jormas.2020.08.013 
Kelvin I. Afrashtehfar a, b, c, d, e, ⁎ , Joannis Katsoulis a, f, Sreenivas Koka g, h, i, Kensuke Igarashi a, j
a Department of Reconstructive Dentistry & Gerodontology, School of Dental Medicine, Faculty of Medicine, University of Bern, 3010 Bern, Switzerland 
b Department of Oral Surgery and Stomatology, School of Dental Medicine, Faculty of Medicine, University of Bern, 3010 Bern, Switzerland 
c Division of Restorative Dental Sciences, College of Dentistry, Ajman University, 346 Ajman City, UAE 
d Department of Restorative Dentistry, Edinburgh Dental Institute, University of Edinburgh, College of Medicine and Veterinary, Lauriston Place, Edinburgh, EH3 9HA, UK 
e Department of Oral Health Sciences, University of British Columbia, Vancouver, BC V6T 1Z3, Canada 
f Department of Preventive & Restorative Sciences, University of Pennsylvania School of Dental Medicine, Philadelphia, PA 19104, USA 
g Division of Advanced Prosthodontics, School of Dentistry, Loma Linda University, Loma Linda, CA 92350, US 
h Advanced Prosthodontics, UCLA School of Dentistry, Los Angeles, CA 90095, USA 
i MIT Sloan School of Management, Massachusetts Institute of Technology, Cambridge, MA 02142, USA 
j Department of Life Science Dentistry, The Nippon Dental University, Niigata 951-8580, Japan 

⁎Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

páginas 8
Iconografías 3
Vídeos 0
Otros 0

Highlights

•
Single and splinted short and extra-short press-fit sintered porous-surfaced implants had similar clinical outcomes in the augmented maxilla.
•
No previous studies have directly compared splinted and non-splinted short implants with a rough surface in sinus lifted scenarios.
•
Prospective studies with adequate sample sizes should confirm whether the prosthesis type is a concern in the aforementioned scenarios.

El texto completo de este artículo está disponible en PDF.

Abstract

Objective

This review primarily evaluated the success, survival and failure rates of implants shorter than 10 mm restored with single-unit or splinted fixed dental prostheses in maxillary sinus augmented sites.

Material and methods

Two reviewers independently performed the systematic search of electronic databases, including MEDLINE, EMBASE and CENTRAL, up to September 2019 with no language restriction. A supplemental hand search consisted of screening 13 journals. The inclusion criteria were: primary studies reporting implant, prosthetic and patient-reported outcome measures (PROMs) of extra-short and short implants placed in conjunction with sinus floor elevation in partially dentate patients, restored with single- and splinted-crowns for direct comparison, with a minimal 1-year follow-up. Weighted arithmetic mean (WAM) of the implant survival was performed according to the type of prosthesis. This was confirmed by using Review Manager software to perform meta-analysis.

Results

Two observational studies reporting on 106 tapered, press-fit, sintered porous-surfaced implants with a length ranging from 5 mm to 9 mm were included in this systematic review. Of these, 20 and 86 implants were restored with single and splinted prostheses, respectively. The risk ratio (RR) was 1.16 (95% CI: .31–4.30, p = .58, I² = 0%) for individually restored implants failure when compared to splinted implants, indicating that short dental implants restored with single crowns could have a 16% higher possibility of failure if compared to implants with splinted crowns. The heterogeneity value was not statistically significative (p = .58). No statistical difference in the implant survival rate of the two types of analysed prostheses was observed after WAM (p= .923). The level of evidence for the included studies ranged from low (4) to fair (2B).

Conclusion

Similar clinical outcomes up to a 9-year follow-up were observed in single and splinted porous-surfaced implants shorter than 10 mm located in sites with sinus lift. However, the conclusion shall be interpreted with caution due to the level of evidence and limited number of included studies included in this systematic review.

El texto completo de este artículo está disponible en PDF.

Keywords : Crowns, Dental implants, Maxilla, Sinus floor augmentation, Outcome assessment, Fixed dental prosthesis.


Esquema


© 2020  The Author(s). Publicado por Elsevier Masson SAS. Todos los derechos reservados.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 122 - N° 3

P. 303-310 - juin 2021 Regresar al número
Artículo precedente Artículo precedente
  • Clinical performance of alveolar ridge augmentation with xenogeneic bone block grafts versus autogenous bone block grafts. A systematic review
  • Luis Sánchez-Labrador, Pedro Molinero-Mourelle, Fabián Pérez-González, Luis Miguel Saez-Alcaide, Jorge Cortés-Bretón Brinkmann, Juan López-Quiles Martínez, Jose María Martínez-González
| Artículo siguiente Artículo siguiente
  • Combined mentalis weakening and periosteal flaps in mandibular anterior alveolar corticotomy-assisted orthodontics with bone grafting
  • I. Saint-Surin, R. Castrot, C. Vandersteen, A. Oueiss, C. Savoldelli

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
La compra de artículos no está disponible en este momento.

¿Ya suscrito a @@106933@@ revista ?

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.