Suscribirse

Relative decrease in hemoglobin and outcomes in patients undergoing kidney transplantation surgery: A retrospective cohort study - 16/09/21

Doi : 10.1016/j.amjsurg.2021.03.002 
Sarah MacIsaac a , Agnihotram V. Ramanakumar b , Chee Saw b, c , Veronique Naessens c , Nasim Saberi d , Marcelo Cantarovich e , Dana Baran e , Steven Paraskevas d , Jean Tchervenkov d , Prosanto Chaudhury d , Shaifali Sandal b, e,
a Faculty of Medicine, McGill University, Montreal, Quebec, Canada 
b Research Institute of the McGill University Health Centre, Montreal, Quebec, Canada 
c Division of Hematology, Department of Medicine, McGill University Health Centre, Montreal, Quebec, Canada 
d Department of Surgery, McGill University Health Centre, Montreal, Quebec, Canada 
e Division of Nephrology, Department of Medicine, McGill University Health Centre, Montreal, Quebec, Canada 

Corresponding author. Royal Victoria Hospital Glen Site, D05-7176, 1001 boul Decarie, Montreal, QC, H4A 3J1, Canada.Royal Victoria Hospital Glen SiteD05-7176, 1001 boul DecarieMontrealQCH4A 3J1Canada

Abstract

Background

Recent surgical literature suggests that a relative decrease in hemoglobin (ΔHb) is predictive of adverse outcomes regardless of the absolute level. We aimed to examine the association between perioperative ΔHb and kidney transplantation (KT) outcomes.

Methods

This was a retrospective cohort study of transplant recipients, where ΔHb =   (Hb0 = hemoglobin pre-KT and Hb1 = lowest hemoglobin 24-h post-KT). The main outcome of interest was immediate graft function (IGF).

Results

Of the 899 eligible patients, 38% experienced IGF, and ΔHb was associated with 36% lower odds of IGF. Also, ΔHb was associated with higher all-cause graft failure and longer length of stay but not death-censored graft failure or mortality. ΔHb ≥30% was the threshold beyond which the odds of IGF were significantly lower even if Hb1 was ≥7 g/dL.

Conclusion

ΔHb is associated with inferior outcomes independent of Hb1; whether it can be used to guide transfusion practices should be explored.

El texto completo de este artículo está disponible en PDF.

Graphical abstract




Image 1

El texto completo de este artículo está disponible en PDF.

Highlights

During kidney transplantation, the impact of perioperative changes in hemoglobin is unknown.
Relative change in recipient hemoglobin is associated with inferior transplant outcomes.
Hemoglobin decline of ≥30% is identified as the threshold for this.
This remains significant even when the lowest perioperative hemoglobin was ≥7 g/dL.
Relative change in hemoglobin should be explored to guide transfusion practices.

El texto completo de este artículo está disponible en PDF.

Keywords : Kidney transplantation, Anemia, Hemoglobin, Transplant outcomes, Blood transfusion


Esquema


© 2021  Elsevier Inc. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 222 - N° 4

P. 825-831 - octobre 2021 Regresar al número
Artículo precedente Artículo precedente
  • Decision making and informed consent in uterus transplant recipients: A mixed-methods study of the Dallas uterus transplant study (DUETS) participants
  • Anji E. Wall, Liza Johannesson, Monica Sok, Ann Marie Warren, Elisa J. Gordon, Giuliano Testa
| Artículo siguiente Artículo siguiente
  • Changes in trends during the COVID-19 lockdown: An urban, Level-1 trauma center's experience
  • Camaleigh A. Jaber, Chih-Yuan Fu, Francesca E. Bryan, Frederic L. Starr, Matthew J. Kaminsky, Leah C. Tatebe, Victoria L. Schlanser, Faran Bokhari

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.