Suscribirse

Increased signal intensity with delayed post contrast 3D-FLAIR MRI sequence using constant flip angle and long repetition time for inner ear evaluation - 31/03/22

Doi : 10.1016/j.diii.2021.10.003 
Samir Osman a, Charlotte Hautefort b, c, Arnaud Attyé d, Alexis Vaussy e, Emmanuel Houdart a, b, Michael Eliezer a, b,
a Department of Neuroradiology, Lariboisière University Hospital, Assistance Publique Hôpitaux de Paris, 75010 Paris, France 
b Université de Paris, Faculté de Médecine, 75010 Paris, France 
c Department of Head and Neck Surgery, Lariboisière University Hospital, Assistance Publique Hôpitaux de Paris, 75010 Paris, France 
d Department of Neuroradiology and MRI, Grenoble Alpes University Hospital, SFR RMN Neurosciences, 38000 Grenoble, France 
e Siemens Healthineers, 93200 Saint-Denis, France 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Highlights

After intravenous administration of gadolinium-based contrast agent, gadolinium passagethrough the blood-labyrinth barrier is weak leading to low concentration of gadolinium in the perilymphatic space.
Elongation of the repetition time (TR) increases the signal intensity ratio (SIR) and contrast-to-noise ratio (CNR) while preserving diagnostic accuracy.
The sensitivity of 3D-FLAIR sequences to low concentration gadolinium in the perilymphatic space is increased (+34.4%) by elongation of the TR.

El texto completo de este artículo está disponible en PDF.

Abstract

Purpose

The purpose of this study was to compare the degree of perilymphatic enhancement between 4 hour post-contrast constant flip angle three-dimensional fluid attenuated inversion recovery (3D-FLAIR) images obtained with short repetition time (TR) and those obtained with long TR.

Materials and methods

This single-center, prospective study included patients who underwent MRI of the inner ear with heavily T2-weighted sequence, 3D-FLAIR sequence with a “short” TR of 10,000 ms (s3D-FLAIR) and with a “long” TR of 16,000 ms (l3D-FLAIR). Signal intensity ratio (SIR) and contrast-to-noise ratio (CNR) obtained with s3D-FLAIR and l3D-FLAIR were quantitatively assessed using region of interest (ROI) method and compared. The morphology of the endolymphatic space on both sequences was also evaluated.

Results

From March 2020 to July 2020, 20 consecutive patients were enrolled (9 women and 11 men; mean age, 52.1 ± 14.5 [SD] years; age range: 29–75 years). On l3D-FLAIR images, mean SIR (21.1 ± 8.8 [SD]; range: 7.6–46.1) was significantly greater than that on s3D-FLAIR images (15.7 ± 6.7 [SD]; range: 5.9–33.4) (P < 0.01). On l3D-FLAIR images, mean CNR (17 ± 8.5 [SD]; range: 2–40) was significantly greater than that on s3D-FLAIR images (12 ± 6.3 [SD]; range: 3.2–29.8) (P < 0.01). Kappa value for inter-rater agreement for endolymphatic hydrops, vestibular atelectasis and perilymphatic fistula were 0.93 (95% CI: 0.74–1), 1 (95% CI: 0.85–1) and 1 (95% CI: 0.85–1) respectively.

Conclusion

This study demonstrates that the sensitivity of 3D-FLAIR sequences to low concentration gadolinium in the perilymphatic space is improved by elongation of the TR, with SIR and CNR increased by +34.4% and +41.3% respectively.

El texto completo de este artículo está disponible en PDF.

Keywords : 3D-FLAIR, Endolymphatic hydrops, Inner ear, Magnetic resonance imaging (MRI)

Abbreviations : 3D, CI, CNR, EH, FLAIR, l3D-FLAIR, MRI, ROI, s3D-FLAIR, SD, SI, SIR, SNR, TE, TR


Esquema


© 2021  Société française de radiologie. Publicado por Elsevier Masson SAS. Todos los derechos reservados.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 103 - N° 4

P. 225-229 - avril 2022 Regresar al número
Artículo precedente Artículo precedente
  • Prediction of clinical response to corticosteroid or platelet-rich plasma injection in plantar fasciitis with MRI: A prospective, randomized, double-blinded study
  • Arnaud Breton, Christophe Leplat, Marie-Christine Picot, Safa Aouinti, Patrice Taourel, Isabelle Laffont, Marc Julia, Catherine Cyteval
| Artículo siguiente Artículo siguiente
  • Pneumodissection during percutaneous renal cryoablation resulting in massive subcutaneous and mediastinal emphysema
  • Koji Tomita, Toshihiro Iguchi, Yusuke Matsui, Mayu Uka, Noriyuki Umakoshi, Takao Hiraki

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.