Suscribirse

Establishing minimal clinically important difference for the UCLA and ASES scores after rotator cuff repair - 13/04/22

Doi : 10.1016/j.otsr.2021.102894 
Eduardo A. Malavolta , Gustavo J. Yamamoto, Daniel T. Bussius, Jorge H. Assunção, Fernando B. Andrade-Silva, Mauro E.C. Gracitelli, Arnaldo A. Ferreira Neto
 Orthopedic and Traumatology Departament, Medicine School of University of São Paulo, Rua Capote Valente 361, apto 212, 05409-001 São Paulo, SP, Brazil 

*Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Background/Hypothesis

Minimal clinically important difference (MCID) is a vital tool in the analysis of clinical results. It allows the determination of clinical relevance of statistical data. Our hypothesis was that specific differences between preoperative and postoperative scores would be able to accurately predict patient perception of improvement and satisfaction as reflected by anchor and distribution-based questions.

Methods

Retrospective cohort with patients that underwent rotator cuff repair. We evaluated the University of California at Los Angeles Shoulder Rating Scale (UCLA) and the American Shoulder and Elbow Surgeons Assessment Form (ASES) before and 12-months after surgery. Anchor-based, distribution-based and minimum detectable change (MDC) approaches were utilized.

Results

We evaluated 289 shoulders. The MCID for the UCLA scale was 4.5 points using the anchor method, 2.5 by the distribution method and 3.6 by MDC. Patients with a baseline score>20 presented a lower MCID (1.5, 1.1 and 1.7, respectively). For the ASES score, the MCID was 6.1 by the anchor method, 10.5 based on the distribution method and 26.3 by MDC. In the group of patients above the 60 point cutoff, the obtained values were 2.4, 4.9 and 13.6, respectively.

Conclusion

The mean MCID value for the UCLA shoulder score is 3.5 points, ranging from 2.5 points (distribution method) to 4.5 points (anchor method). The mean MCID value for the ASES score was 15.2 points, ranging from 6.1 (anchor method) to 26.3 (MDC). Patients groups presenting with higher preoperative scores showed lower MCID values. This fact needs to be considered in postoperative comparisons between treatment groups.

Level of evidence

Basic Science Study, Validation of Outcomes Instruments/Classification Systems.

El texto completo de este artículo está disponible en PDF.

Keywords : Minimal clinically important difference (MCID), Anchor-based methods, Distribution methods, University of California at Los Angeles Shoulder Rating Scale, American Shoulder and Elbow Surgeons Assessment Form


Esquema


© 2021  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 108 - N° 2

Artículo 102894- avril 2022 Regresar al número
Artículo precedente Artículo precedente
  • Implication of bone morphology in degenerative rotator cuff lesions: A prospective comparative study between greater tuberosity angle and critical shoulder angle
  • Gregory Cunningham, Cristina Cocor, Margaret M. Smith, Allan A. Young, Benjamin Cass, Beat K. Moor
| Artículo siguiente Artículo siguiente
  • The IBTIS score; a new prognostic score for arthroscopic biceps tenotomies
  • Olivier Bozon, Léo Chiche, Vincent Salabi, Cyril Lazerges, Michel Chammas, Bertrand Coulet

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2025 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.