Suscribirse

4D flow MRI derived aortic hemodynamics multi-year follow-up in repaired coarctation with bicuspid aortic valve - 31/08/22

Doi : 10.1016/j.diii.2022.04.003 
Gilles Soulat a, b, , Michael B Scott a, e, Ashitha Pathrose a, Kelly Jarvis a, Haben Berhane a, e, Bradley Allen a, Ryan Avery a, Alejandro Roldan Alsate d, Cynthia K Rigsby a, c, Michael Markl a, e
a Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago 60611, IL, USA 
b Université Paris Centre, PARCC INSERM, 75015 Paris, France 
c Department of Medical Imaging, Ann & Robert H. Lurie Children's Hospital of Chicago, Chicago 60611, IL, USA 
d Department of Mechanical Engineering, University of Wisconsin Madison, Madison 53706, WI, USA 
e Department of Biomedical Engineering, McCormick School of Engineering, Northwestern University, Evanston 60208, IL, USA 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Highlights

In patients with bicuspid aortic valve and coarctation repair, mean wall shear stress, peak velocities, and pulse wave velocity remain stable over a median follow-up time of 3.98 years.
Greater baseline peak velocities at the site of the coarctation correlate with aortic narrowing (follow-up vs. baseline diameter) at the coarctation zone (r = -0.642) and descending aorta (r = -0.530).

El texto completo de este artículo está disponible en PDF.

Abstract

Purpose

The purpose of this study was to investigate the relationships between hemodynamic parameters and longitudinal changes in aortic dimensions on four-dimensional (4D) flow magnetic resonance imaging (MRI) in patients with bicuspid aortic valve (BAV) and repaired coarctation.

Materials and methods

The study retrospectively included patients with BAV and childhood coarctation repair who had at least two cardiothoracic MRI examinations including 4D flow MRI at baseline and follow-up. Analysis included the calculation of aortic peak velocities, wall shear stress (WSS), pulse wave velocity (PWV), aortic dimensions and annual growth rates. Differences between examinations were assessed using paired t-test or Wilcoxon signed rank test. Relationships between growth rate and 4D flow metrics were assessed using Pearson or Spearman correlation tests.

Results

The cohort included 15 patients (mean age 35 ± 8 [SD] years, 9 men) with a median follow-up time of 3.98 years (Q1: 2.10; Q3: 4.96). There were no significant differences in aortic mean WSS, peak velocities, and PWV between baseline and follow-up values. Greater baseline peak velocities at the site of the coarctation were strongly associated with aortic narrowing (follow-up vs. baseline diameter) at coarctation zone (r = -0.64; P = 0.010) and moderately in descending aorta (r = -0.53; P = 0.042). In addition, increased baseline WSS in the aortic arch was strongly related with narrowing of the coarctation zone at follow-up (r = -0.64, P = 0.011).

Conclusion

Measures of aortic hemodynamics and aortic WSS are stable over time in patients with BAV with coarctation repair. Increased peak velocity was associated with a progressive narrowing at the site of the coarctation repair.

El texto completo de este artículo está disponible en PDF.

Keywords : Aortic coarctation, 4D flow magnetic resonance imaging (MRI), Bicuspid aortic valve disease

Abbreviations : 3D, 4D, AAo, AArch, ACo, ARB, BAV, BMI, BSA, DAo, MRI, PWV, Q1, Q3, SD, STJ, WSS


Esquema


© 2022  Société française de radiologie. Publicado por Elsevier Masson SAS. Todos los derechos reservados.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 103 - N° 9

P. 418-426 - septembre 2022 Regresar al número
Artículo precedente Artículo precedente
  • Comparison between 1.5-T and 3.0-T MRI for the diagnosis of placenta accreta spectrum disorders
  • Charis Bourgioti, Konstantina Zafeiropoulou, Chara Tzavara, George Daskalakis, Stavros Fotopoulos, Marianna Theodora, Maria Evangelia Nikolaidou, Marianna Konidari, Sofia Gourtsoyianni, Evangelia Panourgias, Vassilis Koutoulidis, Epameinondas Anastasios Martzoukos, Anastasia Evangelia Konstantinidou, Lia Angela Moulopoulos
| Artículo siguiente Artículo siguiente
  • CT-guided microwave ablation of osteoid osteoma: Long-term outcome in 28 patients
  • Lucie Parisot, Franck Grillet, Pierre Verdot, Alexis Danner, Eléonore Brumpt, Sébastien Aubry

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.