Suscribirse

Single-session transarterial chemoembolization combined with percutaneous thermal ablation in liver metastases 3 cm or larger - 03/11/22

Doi : 10.1016/j.diii.2022.05.008 
Adrian Kobe a, , Lambros Tselikas a, b, Frédéric Deschamps a, b, Charles Roux a, Alexandre Delpla a, Eloi Varin a, Antoine Hakime c, Thierry De Baère a, b
a Department of Interventional Radiology, Gustave Roussy-Cancer Center, 94805 Villejuif, France 
b University of Paris-Saclay, 91190 Saint-Aubin, France 
c Centre Imagerie Medicale Bachaumont Paris Centre, 75002 Paris, France 

Corresponding author

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Highlights

Liver metastases 3 cm or larger can be treated percutaneously during a single session using a combination of transarterial chemoembolization and thermal ablation.
A combination of transarterial chemoembolization and thermal ablation is safe.
High local liver metastasis control rates can be achieved by a combined treatment strategy.

El texto completo de este artículo está disponible en PDF.

Abstract

Purpose

The purpose of this study was to evaluate the safety and efficacy of transarterial chemoembolization (TACE) combined with percutaneous thermal ablation in patients with liver metastases 3 cm in diameter or larger.

Materials and methods

This retrospective study included 39 patients with a total of 46 liver metastases treated. There were 14 men and 25 women, with a mean age of 55 ± 13.3 (SD) (age range: 28–77 years). All patients were treated with a combination of TACE and thermal ablation in a single session. Primary outcome was local tumor progression. Secondary outcomes were procedure related complications and systemic disease progression.

Results

Mean tumor size was 3.6 ± 0.6 (SD) cm (range: 3–5 cm). Conventional TACE was performed in 32 liver metastases (32/46; 70%) and drug-eluting beads-TACE in 14 liver metastases (14/46; 30%) followed by radiofrequency ablation in 34 (34/46; 74%), microwave ablation in 11 (11/46; 24%) and cryoablation in one (1/46; 2%) metastasis. Four grade 2 (4/39; 10%) complications were observed. After a mean follow up of 31.9 ± 26.1 (SD) months (range: 2–113 months) overall local tumor progression rate was 15% (7/46). Local tumor progression rate at 12 months was 13% (6/46). Overall systemic disease progression was seen in 29 patients (29/39; 74%) with a systemic disease progression rate at 12 months of 59% (23/39).

Conclusion

Treatment of large liver metastases with TACE and thermal ablation in a single session is safe and achieves high local control rate.

El texto completo de este artículo está disponible en PDF.

Key words : Interventional radiology, Liver metastases, Microwave ablation, Radiofrequency ablation, Transarterial chemoembolization

Abbreviations : AE, CT, cTACE, DEB-TACE, HCC, IQR, IRE, MRI, MWA, RFA, SD, TACE, TAE


Esquema


© 2022  Société française de radiologie. Publicado por Elsevier Masson SAS. Todos los derechos reservados.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 103 - N° 11

P. 516-523 - novembre 2022 Regresar al número
Artículo precedente Artículo precedente
  • Percutaneous image-guided cryoablation with temporary balloon occlusion of the renal artery for the treatment of central renal tumors
  • Pierre-Alexis Autrusseau, Emanuele Boatta, Roberto Luigi Cazzato, Pierre Auloge, Théo Mayer, Julia Weiss, Guillaume Koch, Jean Caudrelier, Pierre De Marini, Afshin Gangi, Julien Garnon
| Artículo siguiente Artículo siguiente
  • Liver imaging reporting and data system (LI-RADS) v2018: Reliability and agreement for assessing hepatocellular carcinoma locoregional treatment response
  • Ahmed S. Abdelrahman, Mena E.Y. Ekladious, Ethar M. Badran, Sherihan S. Madkour

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.