Deep Learning Estimation of 10-2 Visual Field Map Based on Circumpapillary Retinal Nerve Fiber Layer Thickness Measurements - 17/01/23

Doi : 10.1016/j.ajo.2022.10.013 
Alireza Kamalipour , Sasan Moghimi , Pooya Khosravi, Mohammad Sadegh Jazayeri, Takashi Nishida, Golnoush Mahmoudinezhad, Elizabeth H. Li, Mark Christopher, Jeffrey M. Liebmann, Massimo A. Fazio, Christopher A. Girkin, Linda Zangwill, Robert N. Weinreb
 From the Hamilton Glaucoma Center (A.K., S.M., T.N., G.M., E.H.L., M.C., M.A.F., L.Z., R.N.W.), 
 Shiley Eye Institute, Viterbi Family Department of Ophthalmology, University of California San Diego, La Jolla; School of Medicine (P.K.), 
 University of California Irvine, Irvine; Department of Civil, Construction, and Environmental Engineering (M.S.J.), 
 San Diego State University, San Diego, California; Bernard and Shirlee Brown Glaucoma Research Laboratory (J.M.L.), 
 Department of Ophthalmology, Edward S. Harkness Eye Institute, Columbia University Medical Center, New York, New York; and the Department of Ophthalmology and Vision Sciences (M.A.F., C.A.G.), 
 Heersink School of Medicine, The University of Alabama at Birmingham, Birmingham, Alabama, USA. 

1Inquiries to Robert N. Weinreb, Shiley Eye Institute, University of California, San Diego, 9500 Gilman Dr, La Jolla, CA 92093-0946, USAShiley Eye InstituteUniversity of California, San Diego9500 Gilman DrLa JollaCA92093-0946USA

Resumen

Purpose

To estimate central 10-degree visual field (VF) map from spectral-domain optical coherence tomography (SD-OCT) retinal nerve fiber layer thickness (RNFL) measurements in glaucoma with artificial intelligence.

Design

Artificial intelligence (convolutional neural networks) study.

Methods

This study included 5352 SD-OCT scans and 10-2 VF pairs from 1365 eyes of 724 healthy patients, patients with suspected glaucoma, and patients with glaucoma. Convolutional neural networks (CNNs) were developed to estimate the 68 individual sensitivity thresholds of 10-2 VF map using all-sectors (CNNA) and temporal-sectors (CNNT) RNFL thickness information of the SD-OCT circle scan (768 thickness points). 10-2 indices including pointwise total deviation (TD) values, mean deviation (MD), and pattern standard deviation (PSD) were generated using the CNN-estimated sensitivity thresholds at individual test locations. Linear regression (LR) models with the same input were used for comparison.

Results

The CNNA model achieved an average pointwise mean absolute error of 4.04 dB (95% confidence interval [CI] 3.76-4.35) and correlation coefficient (r) of 0.59 (95% CI 0.52-0.64) over 10-2 map and the mean absolute error and r of 2.88 dB (95% CI 2.63-3.15) and 0.74 (95% CI 0.67-0.80) for MD, and 2.31 dB (95% CI 2.03-2.61) and 0.59 (95% CI 0.51-0.65) for PSD estimations, respectively, significantly outperforming the LRA model.

Conclusions

The proposed CNNA model improved the estimation of 10-2 VF map based on circumpapillary SD-OCT RNFL thickness measurements. These artificial intelligence methods using SD-OCT structural data show promise to individualize the frequency of central VF assessment in patients with glaucoma and would enable the reallocation of resources from patients at lowest risk to those at highest risk of central VF damage.

El texto completo de este artículo está disponible en PDF.

Esquema


 Supplemental Material available at AJO.com.


© 2022  Elsevier Inc. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 246

P. 163-173 - février 2023 Regresar al número
Artículo precedente Artículo precedente
  • Leadership in Ophthalmology Professional Organizations: A Descriptive Analysis and Trends, 2002-2022
  • Rachel H. Lee, Kateki Vinod, Alana L. Grajewski
| Artículo siguiente Artículo siguiente
  • What Are the Dry Eye Questionnaires Available in the Scientific Literature Used for? A Scoping Review
  • Mar Sánchez-Brau, Mar Seguí-Crespo, Natalia Cantó-Sancho, Ana Tauste, José María Ramada

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.