Suscribirse

Racial Differences in Detection of Glaucoma Using Retinal Nerve Fiber Layer Thickness and Bruch Membrane Opening Minimum Rim Width - 17/01/23

Doi : 10.1016/j.ajo.2022.10.010 
Nevin W. El-Nimri a, Sasan Moghimi a, , Takashi Nishida a, Adeleh Yarmohammadi a, Linda M. Zangwill a, Huiyuan Hou a, James Proudfoot a, Evan Walker a, Massimo A. Fazio b, Christopher A. Girkin b, Jeffrey M. Liebmann c, Robert N. Weinreb a
a From the Hamilton Glaucoma Center, Shiley Eye Institute, and the Viterbi Family Department of Ophthalmology, University of California San Diego, La Jolla, California (N.W.E.-N., S.M., T.N., A.Y., L.M.Z., H.H., J.P., E.W., R.N.W.) 
b Department of Ophthalmology and Visual Sciences, Heersink School of Medicine, University of Alabama at Birmingham, Birmingham, Alabama (M.A.F., C.A.G.) and 
c Bernard and Shirlee Brown Glaucoma Research Laboratory, Department of Ophthalmology, Edward S. Harkness Eye Institute, Columbia University Irving Medical Center, New York, New York (J.M.L.), USA 

Inquiries to Sasan Moghimi, Hamilton Glaucoma Center and the Shiley Eye Institute, University of California, San Diego, La Jolla, California, USA.Hamilton Glaucoma Center and the Shiley Eye InstituteUniversity of California, San DiegoLa JollaCaliforniaUSA

Resumen

PURPOSE

To compare the sensitivities and specificities of the retinal nerve fiber layer thickness (RNFLT) and Bruch membrane opening minimum rim width (BMO-MRW) reference database-based criteria for detection of glaucoma in individuals of European descent (ED) and individuals of African descent (AD).

DESIGN

Comparative diagnostic analysis by race

METHODS

382 eyes of 255 glaucoma patients (ED = 170, AD = 85) and 94 eyes of 50 healthy individuals (ED = 30, AD = 20) with global and sectoral RNFLT and BMO-MRW measured with Spectralis optical coherence tomography (OCT) were included. Six diagnostic criteria were evaluated: global measurement below the 5th or 1st percentile, ≥1 of the 6 sector measurements below the 5th or 1st percentile, and superotemporal (ST) and/or inferotemporal (IT) measurement below the 5th or 1st percentile. The sensitivities and specificities of these measurements for detection of glaucoma were compared using bootstrapping methods.

RESULTS

ST and/or IT RNFLT below the 5th percentile has the best performance for detection of glaucoma among RNFLT classifications with a sensitivity (95% CI) of 89.5% (86.1, 92.5) and specificity of 87.2% (77.8, 95.1). In AD individuals, sensitivities of ST and IT RNFLT and BMO-MRW measurements below the 5th percentile criteria were lower than in ED individuals (RNFLT: 83.7% vs 92.5%, and BMO-MRW: 72.1% vs 88.5%, respectively), as well as specificities (AD RNFLT: 73.7% and BMO-MRW: 89.5% vs ED RNFLT: 96.4% and BMO-MRW: 98.2%, respectively).

CONCLUSIONS

RNFLT and BMO-MRW had consistently lower diagnostic performance in AD individuals compared with ED individuals. BMO-MRW criteria might fail to detect as many as one-third of eyes with glaucoma, specifically in AD individuals. With the current reference database, RNFLT, and especially BMO-MRW, criteria are not adequate for diagnosing glaucoma in AD individuals.

El texto completo de este artículo está disponible en PDF.

Esquema


 Supplemental Material available at AJO.com.


© 2022  Elsevier Inc. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 246

P. 223-235 - février 2023 Regresar al número
Artículo precedente Artículo precedente
  • Review of Fibrosis in Neovascular Age-Related Macular Degeneration
  • KAI XIONG CHEONG, CHUI MING GEMMY CHEUNG, KELVIN YI CHONG TEO
| Artículo siguiente Artículo siguiente
  • Optical Biometry and IOL Calculation in a Commercially Available Optical Coherence Tomography Device and Comparison With Pentacam AXL
  • Piotr Kanclerz, Kenneth J. Hoffer, Natasza Bazylczyk, Xiaogang Wang, Giacomo Savini

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.