Suscribirse

A novel new 3D volume echo derived method for regurgitation fraction quantification in isolated aortic regurgitation - 13/05/23

Doi : 10.1016/j.acvdsp.2023.04.023 
V. Baland , N. Pace, C. Selton Suty, A. Fraix, O. Huttin, D. Mandry, L. Filippetti
 CHRU Nancy, Nancy, France 

Corresponding author.

Resumen

Introduction

Accurate quantification of chronic aortic regurgitation (AR) using 2D-TTE is sometimes challenging. Cardiac magnetic resonance imaging (CMR) is increasingly used to refine this assessment by estimating measurement of regurgitation fraction (RF), but remains not widely available. 3D echocardiography (3D-ETT) allows a non-invasive approach of right ventricular (RV) and left ventricular (LV) volumes with a good correlation with CMR measurements. The 3D-TTE volume method is based on the comparison of RV and LV stroke volumes, which is then used to calculate the RF of the aortic valve in isolated AR.The primary objective of this study was to investigate the ability of 3D-TTE to assess the severity of chronic AR based on the criterion of regurgitation fraction (RF) obtained by the volume method in comparison to PC-CMR.

Method

We enrolled 42 patients with isolated AR who underwent ASE algorithm-guided 2D echocardiography (2D-TTE), 3D echocardiography and CMR. Regurgitation fraction (RF) was calculated by 3D-TTE using the formula [(LV Stroke Volume–RV Stroke Volume)/LV Stroke Volume]×100. Correlation and concordance between 3D-TTE-RF and PC-CMR-RF were analyzed. Reproducibility of 3D-TTE-RF measurement was evaluated.

Results

Seven (17%) had mild AR, 27 (64%) moderate AR, and 8 (19%) severe AR in PC-CMR. Mean RF was 32.7±13.9% by 3D-TTE and 30,7±14,9% by PC-CMR-RF (P<0,05). 3D-TTE-RF and PC-CMR-RF had a good correlation (r=0.90, P<0,05). We found a good intra-operator (r:0.95, P<0.05) and inter-operator (r:0.87, P<0.05) reproductibility. The final gradation of AR was concordant between 3D TTE and PC-CMR in 88% of the cases.

Conclusion

The assessment of isolated aortic regurgitation fraction in 3D-TTE by the volumetric method is a feasible and reproducible method in daily clinical practice, with a good correlation to PC-CMR. Estimation of the aortic regurgitation fraction in (Figure 1).

El texto completo de este artículo está disponible en PDF.

Esquema


© 2023  Publicado por Elsevier Masson SAS.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 15 - N° 3

P. 254-255 - juin 2023 Regresar al número
Artículo precedente Artículo precedente
  • Multimodal imaging assessment of mitral valve area after transcatheter mitral valve implantation: A three-dimensional echocardiographic and CT scan study
  • M. Jullien, M. Urena, D. Himbert, C. Nguyen, E. Brochet, P. Ou, B. Iung
| Artículo siguiente Artículo siguiente
  • Impact of fibrosis extend on multiparametric assessment for ventricular arrhythmias risk in non-ischemic dilated cardiomyopathy
  • G. Chassard, L. Filippetti, N. Girerd, N. Hammache, N. Sadoul, O. Huttin, P.Y. Marie, I. Magnin Poull

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.