Suscribirse

Three-Dimensional Quantitative Description of the Implantable Collamer Lens in the Ocular Anterior Segment of Patients With Myopia - 12/07/23

Doi : 10.1016/j.ajo.2023.03.005 
Tong Zhang 1, Fanfan Huang 1, Ning Gao 1, Miaomiao Du 1, Hong Cheng 1, Wanyao Huang 1, Yan Ji 2, Shijie Zheng 2, Wenjuan Wan 1, 2, , Ke Hu 1, 2, ,
1 From Chongqing Medical University (T.Z., F.H., N.G., M.D., H.C., W.H., W.W., K.H.) and The First Affiliated Hospital of Chongqing Medical University (Y.J., S.Z., W.W., K.H.), Chongqing Key Laboratory of Ophthalmology, Chongqing Eye Institute, Chongqing Branch (Municipality Division) of National Clinical Research Center for Ocular Diseases, Chongqing, China. 
2 The First Affiliated Hospital of Chongqing Medical University, Chongqing Key Laboratory of Ophthalmology, Chongqing Eye Institute, Chongqing Branch (Municipality Division) of National Clinical Research Center for Ocular Diseases, Chongqing, China. 

#Inquiries to Wenjuan Wan, The First Affiliated Hospital of Chongqing Medical University, Chongqing Key Laboratory of Ophthalmology, Chongqing Eye Institute, Chongqing Branch (Municipality Division) of National Clinical Research Center for Ocular Diseases, Chongqing, China or Ke Hu, The First Affiliated Hospital of Chongqing Medical University, Chongqing Key Laboratory of Ophthalmology, Chongqing Eye Institute, Chongqing Branch (Municipality Division) of National Clinical Research Center for Ocular Diseases, Chongqing, ChinaThe First Affiliated Hospital of Chongqing Medical UniversityChongqing Key Laboratory of Ophthalmology, Chongqing Eye Institute, Chongqing Branch (Municipality Division) of National Clinical Research Center for Ocular DiseasesChongqingChina

Resumen

Purpose

To describe the 3-dimensional (3D) location of the implantable collamer lens (ICL) quantitatively in the posterior ocular chamber of patients with myopia.

Design

Cross-sectional study.

Methods

To obtain visualization models before and after mydriasis, an automatic 3D imaging method based on swept-source optical coherence tomography was created. Parameters like the ICL lens volume (ILV), the tilt of the ICL and crystalline lens, the vault distribution index, and topographic maps were evaluated to describe the ICL location. Using a paired sample t test and the Wilcoxon signed rank test, the difference between nonmydriasis and postmydriasis conditions was compared.

Results

The study investigated 32 eyes from 20 patients. The 3D central vault did not differ significantly before (P = .994) or after mydriasis (P = .549) compared with the 2D central vault. After mydriasis, the 5-mm ILV decreased by 0.85 mm2 (P = .016), and the vault distribution index increased significantly (P = .001). The ICL and the crystalline lens exhibited tilt (nonmydriasis: ICL total tilt 3.78 ± 1.85 degrees, lens total tilt 4.03 ± 1.53 degrees; postmydriasis: ICL total tilt 3.84 ± 1.56 degrees, lens total tilt 4.09 ± 1.64 degrees). The phenomenon of asynchronous tilt of the ICL and lens was found in 5 eyes, leading to the spatially asymmetric distribution of the ICL–lens distance.

Conclusion

The 3D imaging technique provided exhaustive and reliable data for the anterior segment. The visualization models offered multiple perspectives on the ICL in the posterior chamber. Before and after mydriasis, the intraocular ICL position was described by the 3D parameters.

El texto completo de este artículo está disponible en PDF.

Esquema


 Supplemental Material available at AJO.com.


© 2023  Elsevier Inc. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 252

P. 59-68 - août 2023 Regresar al número
Artículo precedente Artículo precedente
  • Exploring Imaging Characteristics Associated With Disease Activity in Idiopathic Multifocal Choroiditis: A Multimodal Imaging Approach
  • Evianne L. de Groot, Ninette H. ten Dam-van Loon, Carlyn V. Kouwenberg, Joke H. de Boer, Jeannette Ossewaarde-van Norel
| Artículo siguiente Artículo siguiente
  • Endogenous Endophthalmitis From a Klebsiella pneumoniae Liver Abscess: The Incidence, Risk Factors, and Utility of Imaging
  • EunAh Kim, Iksoo Byon, Jae Jung Lee, Young Mi Seol, Han Jo Kwon, Sung Who Park, Ji Eun Lee

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.