Suscribirse

Comparative study of stability between two different fixation systems after orthognathic surgery in mandibular prognathism skeleton - 25/08/23

Doi : 10.1016/j.jormas.2023.101431 
Pawaris Chanachol a, Net-nada Chongruangsri b, Sirida Arunjaroensuk c, Sunisa Rochanavibhata c, Kiti Siriwatana c, Atiphan Pimkhaokham c,
a Department of oral and maxillofacial surgery, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand 
b Royal Thai Navy hospital, Bangkok, Thailand 
c Department of maxillofacial surgery, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand 

Corresponding author at: Faculty of Dentistry, Chulalongkorn University, 34 Henri-Dunant Road, Wongmai, Patumwan, Bangkok, 10330, Thailand.Faculty of DentistryChulalongkorn University34 Henri-Dunant RoadWongmai, PatumwanBangkok10330Thailand

Abstract

Objective

This study is intended to compare the skeleton stability of bioabsorbable and titanium systems after orthognathic surgery in mandibular prognathism patients.

Study design

A Retrospective study of 28 mandibular prognathism patients who underwent BSSRO setback surgery at Chulalongkorn University. Both titanium and the bioabsorbable group would take lateral cephalometrics immediately postoperative in 1-week(T0), 3(T1), 6(T2), and 12(T3) months. These radiographs were analyzed with Dolphin imaging programTM. The vertical, horizontal, and angular indices were measured. To compare immediately postoperative and follow-up periods within the group, the Friedman difference was used, and the Man-Whitney U test was used between the two groups.

Result

The measurements within the group presented no statistically significant differences. But this study showed that at T0-T1, there was a statistically significant difference between the two groups in the mean of Me in horizontal linear measurement. T0-T2 found differences between Me in both horizontal and vertical linear measurements, and the difference between ANB. The differences between B-point, Pog, and Me in vertical linear measurements at T0-T3 were also reported.

Conclusion

The significant difference values were within the normal range which indicated that using the bioabsorbable system could be well maintained as well as the titanium system.

Statement of clinical relevance

The second operation for removing titanium plate and screw after conventional orthognathic surgery may leads patient discomforts. While a resorbable system might be the role change if the stability is place on the same level.

El texto completo de este artículo está disponible en PDF.

Keywords : Resorbable plate, Bioabsorbable plate, Skeleton stability, Orthognathic


Esquema


© 2023  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 124 - N° 4

Artículo 101431- septembre 2023 Regresar al número
Artículo precedente Artículo precedente
  • Evaluation of maxillary palatal process pneumatization by cone-beam computed tomography
  • Gozde Serindere, Mehmet Serindere, Kaan Gunduz
| Artículo siguiente Artículo siguiente
  • Intraoral exophytic lesion in an adolescent: A case report of myoepithelioma with unique clinical presentation
  • Cynthia Marina Urias Barreras, Ana Karen Soto Sañudo, Jorge Vega Imperial, Alberto Rodríguez Archilla

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.