Which method for femoral component sizing when performing kinematic alignment TKA? An in silico study - 23/03/24

Doi : 10.1016/j.otsr.2023.103769 
Fasen Huang a, b, Simon Harris a, Tianyu Zhou a, Gabriel B. Roby c, Benjamin Preston d, Charles Rivière a, c, e,
a MSK laboratory, Department of Surgery and Cancer, Imperial College London, London W12 0BZ, United Kingdom 
b Shenzhen Traditional Chinese Medicine Hospital, Shenzhen 518033, China 
c Bordeaux Arthroplasty Research Institute, 6, rue Georges-Negrevergne, 33700 Mérignac, France 
d Imperial College London School of Medicine, South Kensington Campus, London SW7 2DD, United Kingdom 
e Clinique du Sport Bordeaux-Mérignac, 4, rue Georges-Negrevergne, 33700 Mérignac, France 

*Corresponding author. MSK laboratory, Department of Surgery and Cancer, Imperial College London, London W12 0BZ, United Kingdom.MSK laboratory, Department of Surgery and Cancer, Imperial College LondonLondonW12 0BZUnited Kingdom

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Introduction

The kinematically alignment (KA) technique for TKA aims to reproduce the pre-arthritic knee anatomy, including both the femoro-tibial and femoro-patellar joints. An in silico study was conducted to compare 3 different femoral component sizing techniques to identify the anatomical landmark which allows closest restoration of the native trochlear anatomy. Our study's question was: what was the best method for sizing the femoral component when performing KA-TKA? It was hypothesized that sizing the femoral component by aiming to restore the groove height would be the best method to restore the native trochlear anatomy.

Methods

GMK sphere® (Medacta) femoral component 3D models were virtually kinematically aligned on 30 tri-dimensional (3D) bony osteoarthritis knee models. The femoral component was mediolaterally positioned to match distal native and prosthetic grooves. Three methods were used to size the femoral component: a conventional method with the anterior femoral cut flush to the femoral cortex (C-KATKA) and two alternative personalized methods aiming to recreate either the medial facet's height (ATM-KATKA) or the groove's height (ATG-KATKA). In-house analysis software was used to compare native and prosthetic trochlear articular surfaces and mediolateral implant overhangs.

Results

Compared with the C-KATKA, ATG-KATKA and ATM-KATKA techniques increased the component size by a mean of 0.90 (SD 0.31, min 0.5 to max 1.5) (p<0.001) and 1.02 (SD 0.31, min 0.5 to max 1.5) (p<0.001), respectively. C-KATKA technique substantially proximally understuffed the trochleae with maximum values of 7.11mm (SD 1.39, min 3.93mm to max 10.57mm) in the medial facet, 4.72mm (SD 1.27, min 1.46mm to max 6.86mm) in the lateral facet and 4.51mm (SD 1.40, min 1.92mm to max 7.30mm) in the groove, respectively. Alternative techniques understuffed medial facet with maximum values of 5.07mm (SD 1.29, min 2.83mm to max 8.34mm) and 4.70mm (SD 1.52, min 0.83mm to max 8.04mm) for ATG-KATKA and ATM-KATKA techniques, respectively. There was no significant understuffing of the groove or lateral facet for alternative techniques (ATM and ATG). The ATM-KATKA and ATG-KATKA techniques generated mediolateral implant overhang, mainly postero-lateral, with a rate of 90.0% and 86.7%, respectively. In this study, no mediolateral implant overhang was found for C-KATKA.

Discussion/conclusion

The C-KATKA technique substantially understuffs the native trochlear articular surfaces in medial, lateral and groove parts. Alternative techniques (ATM-KATKA and ATG-KATKA) for sizing the femoral component better restore the native trochlear anatomy but also generate a high rate of postero-lateral implant overhangs. Would this postero-lateral implant overhang be clinically deleterious remains unknown? The aspect ratio of contemporary femoral TKA implants can probably be optimized to allow a better anatomical restoration of the anterior femoral compartment.

Level of evidence

II, in silico study.

El texto completo de este artículo está disponible en PDF.

Keywords : Total knee arthroplasty, Personalized, Anterior compartment, Trochlea offset, Biomechanics, Joint perception


Esquema


© 2023  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 110 - N° 2

Artículo 103769- avril 2024 Regresar al número
Artículo precedente Artículo precedente
  • Total knee arthroplasty: Where are we after the “kinematic alignment” wave?
  • Matthew Arnold, Sébastien Lustig, Gilles Pasquier, J. Donald Hansom
| Artículo siguiente Artículo siguiente
  • Distal femoral torsion positioning in total knee arthroplasty shows equal reliability using a computer-assisted system or a robotic arm
  • Marie-Camille Sabaté Ferris, Baptiste Picart, Philippe Boisrenoult, Nicolas Pujol

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2025 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.