Suscribirse

Flow quantification within the aortic ejection tract using 4D flow cardiac MRI in patients with bicuspid aortic valve: Implications for the assessment of aortic regurgitation - 06/12/24

Doi : 10.1016/j.diii.2024.09.001 
Lan-Anh Nguyen a, b, Umit Gencer a, b, Guillaume Goudot a, b, Damian Craiem c, Mariano E. Casciaro c, Charles Cheng b, Emmanuel Messas a, b, Elie Mousseaux a, b, Gilles Soulat a, b,
a Université Paris Cité, INSERM, PARCC, Paris 75015, France 
b Hôpital Européen Georges Pompidou, Assistance Publique-Hôpitaux de Paris, 75015 Paris, France 
c Instituto de Medicina Traslacional, Trasplante y Bioingeniería (IMeTTyB), Universidad Favaloro-CONICET, CP 1078 Buenos Aires, Argentina 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Highlights

As with 2D flow cardiac MRI, regurgitant and forward volumes vary along the aortic ejection tract with 4D flow cardiac MRI in patients with bicuspid aortic valve.
Tracking the aortic root along the cardiac cycle has little effect on flow quantification with 4D flow cardiac MRI in patients with bicuspid aortic valve.
Using flow consistency, the sinotubular junction seems to be the best level for assessing regurgitation in patients with bicuspid aortic valve using 4D flow cardiac MRI.
The aortic annulus seems to be the best plane for forward flow quantification in patients with bicuspid aortic valve.

El texto completo de este artículo está disponible en PDF.

Abstract

Purpose

The purpose of this study was to evaluate the performance of four-dimensional (4D) flow cardiac MRI in quantifying aortic flow in patients with bicuspid aortic valve (BAV).

Materials and methods

Patients with BAV who underwent transthoracic echocardiography (TTE) and 4D flow cardiac MRI were prospectively included. Aortic flow was quantified using two-dimensional phase contrast velocimetry at the sinotubular junction and in the ascending aorta and using 4D flow in the regurgitant jet, in the left ventricular outflow tract, at the aortic annulus, the sinotubular junction, and the ascending aorta, with or without anatomical tracking. Flow quantification was compared with ventricular volumes, pulmonary flow using Pearson correlation test, bias and limits of agreement (LOA) using Bland Altman method, and with multiparametric transthoracic echocardiography quantification using weighted kappa test.

Results

Eighty-eight patients (63 men, 25 women) with a mean age of 50.5 ± 14.8 (standard deviation) years (age range: 20.8–78.3) were included. Changes in flow with or without tracking were modest (< 5 mL). The best correlation was obtained at the aortic annulus for forward volume ( r = 0.84; LOA [-28.4; 25.3] mL) and at the regurgitant jet and sinotubular junction for regurgitant volume ( r = 0.68; LOA [-27.8; 33.8] and r = 0.69; LOA [-28.6; 24.2] mL). A combined approach for regurgitant fraction and net volume calculations using forward volume measured at ANN and regurgitant volume at sinotubular junction performed better than each level taken separately ( r = 0.90; LOA [-20.7; 10.0] mL and r = 0.48, LOA [-33.8; 33.4] %). The agreement between transthoracic echocardiography and 4D flow cardiac MRI for aortic regurgitation grading was poor (kappa, 0.13 to 0.42).

Conclusion

In patients with BAV, aortic flow quantification by 4D flow cardiac MRI is the most accurate at the annulus for the forward volume, and at the sinotubular junction or directly in the jet for the regurgitant volume.

El texto completo de este artículo está disponible en PDF.

Keywords : 4D flow cardiac MRI, Aortic valve insufficiency, Bicuspid aortic valve disease, Cardiac magnetic resonance imaging

Abbreviations : 2D, 4D, AA, ANN, AR, BAV, CI, COMB, EDV, ESV, Fvol, LOA, LV, LVOT, LVSV, MRI, PA, PC, RF%, ROI, RV, Rvol, SD, SSFP, STJ, SV, TR, TTE


Esquema


© 2024  Société française de radiologie. Publicado por Elsevier Masson SAS. Todos los derechos reservados.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 105 - N° 12

P. 498-506 - décembre 2024 Regresar al número
Artículo precedente Artículo precedente
  • Diagnostic performance and relationships of structural parameters and strain components for the diagnosis of cardiac amyloidosis with MRI
  • Youssef Zaarour, Islem Sifaoui, Haifa Remili, Mounira Kharoubi, Amira Zaroui, Thibaud Damy, Jean-François Deux
| Artículo siguiente Artículo siguiente
  • Spontaneous necrosis and regression of focal nodular hyperplasia
  • Thi Thuy Linh Nguyen, Brigitte Le Bail, Nora Frulio

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.