Suscribirse

Coronary artery disease detection using deep learning and ultrahigh-resolution photon-counting coronary CT angiography - 18/02/25

Doi : 10.1016/j.diii.2024.09.012 
Jan M. Brendel a, Jonathan Walterspiel a, Florian Hagen a, Jens Kübler a, Andreas S. Brendlin a, Saif Afat a, Jean-François Paul b, c, Thomas Küstner d, Konstantin Nikolaou a, Meinrad Gawaz e, Simon Greulich e, Patrick Krumm a, , Moritz T. Winkelmann a
a Department of Radiology, Diagnostic and Interventional Radiology, University of Tübingen, 72076, Germany 
b Institut Mutualiste Montsouris, Department of Radiology, Cardiac Imaging, 75014 Paris, France 
c Spimed-AI, 75014 Paris, France 
d Department of Radiology, Diagnostic and Interventional Radiology, Medical Image and Data Analysis (MIDAS.lab), University of Tübingen, 72076, Germany 
e Department of Internal Medicine III, Cardiology and Angiology, University of Tübingen, 72076, Germany 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Highlights

Artificial intelligence shows remarkable performance in detecting significant coronary artery disease on ultrahigh-resolution photon-counting CT.
Artificial intelligence may serve as a valuable pre-reading tool to assist human readers for coronary artery disease detection on photon-counting coronary CT angiography in daily clinical practice.
Integrating artificial intelligence for coronary artery disease detection could improve workflow efficiency and help radiologists manage increasing workloads.

El texto completo de este artículo está disponible en PDF.

Abstract

Purpose

The purpose of this study was to evaluate the diagnostic performance of automated deep learning in the detection of coronary artery disease (CAD) on photon-counting coronary CT angiography (PC-CCTA).

Materials and methods

Consecutive patients with suspected CAD who underwent PC-CCTA between January 2022 and December 2023 were included in this retrospective, single-center study. Non-ultra-high resolution (UHR) PC-CCTA images were analyzed by artificial intelligence using two deep learning models (CorEx, Spimed-AI), and compared to human expert reader assessment using UHR PC-CCTA images. Diagnostic performance for global CAD assessment (at least one significant stenosis ≥ 50 %) was estimated at patient and vessel levels.

Results

A total of 140 patients (96 men, 44 women) with a median age of 60 years (first quartile, 51; third quartile, 68) were evaluated. Significant CAD on UHR PC-CCTA was present in 36/140 patients (25.7 %). The sensitivity, specificity, accuracy, positive predictive value), and negative predictive value of deep learning-based CAD were 97.2 %, 81.7 %, 85.7 %, 64.8 %, and 98.9 %, respectively, at the patient level and 96.6 %, 86.7 %, 88.1 %, 53.8 %, and 99.4 %, respectively, at the vessel level. The area under the receiver operating characteristic curve was 0.90 (95 % CI: 0.83–0.94) at the patient level and 0.92 (95 % CI: 0.89–0.94) at the vessel level.

Conclusion

Automated deep learning shows remarkable performance for the diagnosis of significant CAD on non-UHR PC-CCTA images. AI pre-reading may be of supportive value to the human reader in daily clinical practice to target and validate coronary artery stenosis using UHR PC-CCTA.

El texto completo de este artículo está disponible en PDF.

Keywords : Computed tomography, Coronary artery disease, Deep learning, Photon-counting CT, Ultrahigh resolution

Abbreviations : AI, AUC, CAD, CAD-RADS, CCTA, CDTI vol , CI, DLP, FFR, FFRai, PC, PC-CCTA, PPV, NPV, SD, UHR


Esquema


© 2024  The Author(s). Publicado por Elsevier Masson SAS. Todos los derechos reservados.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 106 - N° 2

P. 68-75 - février 2025 Regresar al número
Artículo precedente Artículo precedente
  • Ultra-high resolution spectral photon-counting CT outperforms dual layer CT for lung imaging: Results of a phantom study
  • Hugo Lacombe, Joey Labour, Fabien de Oliveira, Antoine Robert, Angèle Houmeau, Marjorie Villien, Sara Boccalini, Jean-Paul Beregi, Philippe C. Douek, Joël Greffier, Salim A. Si-Mohamed
| Artículo siguiente Artículo siguiente
  • Generative AI smartphones: From entertainment to potentially serious risks in radiology
  • Loïc Duron, Philippe Soyer, Augustin Lecler

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.