Suscribirse

Mineralized tissue visualization with MRI: Practical insights and recommendations for optimized clinical applications - 06/05/25

Doi : 10.1016/j.diii.2024.11.001 
Pedro Augusto Gondim Teixeira a, b, ⁎ , Hippolyte Kessler a, Lieve Morbée c, Nicolas Douis a, b, Fatma Boubaker a, Romain Gillet a, b, Alain Blum a
a Guilloz Imaging Department, Central Hospital, University Hospital Center of Nancy, Nancy 54035, France 
b Université de Lorraine, Inserm, IADI, Nancy 54000, France 
c Department of Radiology, Ghent University Hospital, Ghent 9000, Belgium 

⁎ Corresponding author at: Guilloz Imaging Department, Central Hospital, University Hospital Center of Nancy, Nancy 54035, France. Guilloz Imaging Department Central Hospital University Hospital Center of Nancy Nancy 54035 France

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Highlights

•
Mineralized tissue MRI techniques are promising for bone morphology and fracture detection but remain less accurate than computed tomography for subtle bone details.
•
Although mineralized tissue MR images resemble CT images, they are subjected to various types of artifacts and should not be interpreted like conventional CT images.
•
T1-weighted three-dimensional gradient echo sequences appear as robust and widely available solutions for mineralized tissue MRI providing high-quality images with a good signal-to-noise ratio.
•
Although they convey limited signal-to-noise ratio, ultra-short and zero echo time MRI sequences are the best ones for detecting calcification within tendons and ligaments.
•
Artificial intelligence-generated synthetic CT offers high-quality images with great potential, but comparison with the other mineralized tissue MRI techniques are needed.

El texto completo de este artículo está disponible en PDF.

Abstract

Magnetic resonance imaging (MRI) techniques that enhance the visualization of mineralized tissues (hereafter referred to as MT-MRI) are increasingly being incorporated into clinical practice, particularly in musculoskeletal imaging. These techniques aim to mimic the contrast provided by computed tomography (CT), while taking advantage of MRI's superior soft tissue contrast and lack of ionizing radiation. However, the variety of MT-MRI techniques, including three-dimensional gradient-echo, ultra-short and zero-echo time, susceptibility-weighted imaging, and artificial intelligence-generated synthetic CT, each offer different technical characteristics, advantages, and limitations. Understanding these differences is critical to optimizing clinical application. This review provides a comprehensive overview of the most commonly used MT-MRI techniques, categorizing them based on their technical principles and clinical utility. The advantages and disadvantages of each approach, including their performance in bone morphology assessment, fracture detection, arthropathy-related findings, and soft tissue calcification evaluation are discussed. Additionally, technical limitations and artifacts that may affect image quality and diagnostic accuracy, such as susceptibility effects, signal-to-noise ratio issues, and motion artifacts are addressed. Despite promising developments, MT-MRI remains inferior to conventional CT for evaluating subtle bone abnormalities and soft tissue calcification due to spatial resolution limitations. However, advances in deep learning and hardware innovations, such as artificial intelligence-generated synthetic CT and ultrahigh-field MRI, may bridge this gap in the future.

El texto completo de este artículo está disponible en PDF.

Keywords : Gradient echo, Musculoskeletal imaging, Susceptibility weighted imaging, Synthetic CT, Zero echo time

Abbreviations : 3D, AI, B0, CBCT, CT, FOV, FLASH, GRE, HU, ICC, LAVA, MRI, MT-MRI, PETRA, RF, SNR, SWI, TE, UTE, ZTE, THRIVE, VIBE


Esquema


© 2024  The Authors. Publicado por Elsevier Masson SAS. Todos los derechos reservados.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 106 - N° 5

P. 147-156 - mai 2025 Regresar al número
Artículo precedente Artículo precedente
  • Robotics and artificial intelligence in the real world of interventional radiology: Innovation or illusion?
  • Baptiste Bonnet, Lambros Tselikas
| Artículo siguiente Artículo siguiente
  • Evaluation of navigation and robotic systems for percutaneous image-guided interventions: A novel metric for advanced imaging and artificial intelligence integration
  • Francois H. Cornelis, Dimitrios K Filippiadis, Philipp Wiggermann, Stephen B. Solomon, David C. Madoff, Laurent Milot, Sylvain Bodard

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.