Suscribirse

What is the lower limb length discrepancy after arthroplasty for proximal femoral fracture? A prospective, multicenter observational study of 590 hips - 03/06/25

Doi : 10.1016/j.otsr.2024.104119 
Fredson Razanabola a, Henri-Antoine Peuchot b, Roger Erivan c, , Xavier Flecher b, Marie Pierret d, Hervé Nieto e, Christophe Chantelot f, Mehdi Hormi-Menard f, Benoît Villain g, Pierre Martz h, François Loubignac i, Olivier Gastaud j, Régis Bernard de Dompsure k, Anthony Viste l, Philippe Boisrenoult m, Erwan Pansard n, Pierre Klein o, Romain Rey p, Alain Duhamel q, Henri Migaud f

SoFCOTr

a CHU Orléans, Hôpital La Source, Service de chirurgie Orthopédique et Traumatologique, 14 avenue de l’hôpital, CS 86 709, 45100 Orléans, France 
b Institut du Mouvement et de l’appareil Locomoteur, Département de Chirurgie Orthopédique, Université Aix-Marseille, Hôpital Sainte-Marguerite, 270 Boulevard Sainte-Marguerite, 13009 Marseille, France 
c Université Clermont Auvergne, CHU Clermont-Ferrand, CNRS, SIGMA Clermont, ICCF, F-63000 Clermont-Ferrand, France 
d Höpitaux Civils de Colmar, Service d’Orthopédie Traumatologie, Hôpital Louis Pasteur, 39 Avenue de la Liberté, 68024 Colmar, France 
e Centre Hospitalier de Niort, 40 avenue Charles de Gaulle, 79021 Niort, France 
f Université de Lille, CHRU de Lille, Hôpital Salengro, Service d’Orthopédie – Traumatologie, Av du Pr Emile-Laine, 59000 Lille, France 
g CHU Antoine-Béclère, AP-HP, 157 rue de la Porte de Trivaux, 92140 Clamart, France 
h CHU Dijon, Hôpital François Mitterrand, 2 boulevard Maréchal de Lattre de Tassigny, 21079 Dijon, France 
i Centre Hospitalier Intercommunal Toulon-la Seyne/mer (CHITS), Service de chirurgie orthopédique et traumatologique, Hôpital Sainte-Musse, 4, avenue Sainte-Claire Deville, 83056 Toulon Cedex, France 
j Centre Hospitalier de Cannes Simone Veil, Service de Chirurgie Orthopédique et Traumatologique, 15 Avenue des Broussailles, 06401 Cannes, France 
k CHU de Nice, Hôpital Pasteur, 30 voie Romaine, 06100 Nice, France 
l CHU Lyon Sud, 165 chemin du Grand Revoyet, 69495 Oullins-Pierre-Bénite, France 
m Centre Hospitalier de Versailles, Service de chirurgie Orthopédique et Traumatologique, 177 rue de Versailles, 78150 Le Chesnay, France 
n CHU Paris Ouest, Hôpital Ambroise Paré, AP-HP, 9 Avenue Charles de Gaulle, 92100 Boulogne-Billancourt, France 
o Hôpitaux Universitaires de Strasbourg, Service de chirurgie orthopédique et de traumatologie, Hôpital de Hautepierre, 1, Avenue Molière, 67098 Strasbourg, France 
p Centre Hospitalier de Dieppe, Avenue Pasteur, 76200 Dieppe, France 
q Université de Lille, CHU Lille, ULR2694 METRICS : évaluation des technologies de santé et des pratiques médicales, F59000 Lille, France 
r Société Française de Chirurgie Orthopédique et Traumatologique, 56 rue Boissonade, 75014 Paris Cedex, France 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Introduction

Lower limb length discrepancy (LLD) following hip arthroplasty after proximal femoral fracture (PFFA) is little studied. The aim of this work was to answer the following questions: 1) What are the incidence and mean values ​​of LLD after PFFA? 2) What are the clinical consequences (tolerance) of LLD after PFFA? 3) Can we identify risk factors for LLD after PFFA? 4) Is there a significant difference in terms of LLD after PFFA to treat intra- versus extra-capsular fractures?

Hypothesis

LLD after proximal femoral fracture arthroplasty is rare but has good clinical tolerance, given the low functional demands of the patients.

Patients and methods

This is a multicenter prospective observational cohort study (15 centers), including 590 patients, operated on for hip arthroplasty for proximal femur fracture between May 2022 and June 2023. The mean age was 81.74 years (±10.72). The clinical and radiological measurement of LLD was carried out between the 6th week and the 6th month postoperatively. A positive LLD meant that the operated side was lengthened, a negative LLD meant that it was shortened. Clinical tolerance was measured using objective (Merle d’Aubigné (PMA) and Harris (HHS)) and subjective (Oxford-12 and Forgotten Joint Score (FJS)) functional scores as well as autonomy measured using the Parker score.

Results

Clinical and radiological measurements of LLD were highly correlated (p < 0.001), and showed an overall shortening trend of −0.03 mm (±4.99). In total, 265/590 patients (45%) had a LLD greater than 3 mm, 131/590 (22%) had an LLD greater than 5 mm, and 24/590 (4%) had a LLD greater than 10 mm. A LLD beyond ±3 mm significantly worsened all functional scores compared to an LLD below this threshold (PMA: 12.2 ± 3.2 vs. 12.9 ± 3.6 (p = 0.020); HHS: 62.7 ± 20.3 vs. 66.5 ± 19.3 (p = 0.027); FJS: 61.5 ± 28.8 vs. 72.5 ± 25.6 (p < 0.001); and the Oxford-12 score: 29.2 ± 9.7 vs. 26 ± 9.4 (p < 0.001)). However, no significant difference was observed for the autonomy (Parker score 4.7 ± 2.5 versus 4.8 ± 2.7 (p = 0.58)). Female gender (+0.43 mm ± 4.71 (p < 0.001)) and cementing of the femoral implant (+0.42 mm ± 4.57 (p = 0.014)) were associated to lengthening. Cementless stems (−0.41 mm ± 5.29 (p = 0.014)), general anesthesia without curare (−1.8 mm ± 5.96 (p = 0.007)), and the Röttinger and Watson-Jones approaches (−1.34 mm ± 4.57 (p = 0.04)) were associated to shortening. There was no difference between LLD after intracapsular fracture (−0.06 mm ± 5) and extracapsular fracture (+0.9 mm ± 3 (p = 0.45)).

Discussion

Our results are consistent with the literature data which is sparse on the subject, with 78% of LLD in our series ranging between +5 and −5 mm. Functional consequences were observed as soon as the 3 mm threshold was exceeded but without effect on autonomy. Only 4% of patients had a centimeter inequality.

Level of evidence

IV; prospective study without control group.

El texto completo de este artículo está disponible en PDF.

Keywords : Leg length discrepancy (LLD), Hip arthroplasty, Femoral neck fracture, Proximal femoral fracture, Hip fracture, Intracapsular fracture, LLD tolerance threshold


Esquema


© 2024  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 111 - N° 4

Artículo 104119- juin 2025 Regresar al número
Artículo precedente Artículo precedente
  • Machine learning models based on a national-scale cohort accurately identify patients at high risk of deep vein thrombosis following primary total hip arthroplasty
  • Ziwei Huang, Anirudh Buddhiraju, Tony Lin-Wei Chen, MohammadAmin RezazadehSaatlou, Shane Fei Chen, Blake M. Bacevich, Pengwei Xiao, Young-Min Kwon
| Artículo siguiente Artículo siguiente
  • Risk factors for complications and readmission after total hip or knee replacement with ERAS
  • Mohammad Alajji, Julien Erard, Béatrice Ferreboeuf, Michel-Henry Fessy, Anthony Viste

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.