Abstract

Purpose

Diffusion-weighted MRI is widely used to probe brain microstructure, but its signal reflects both diffusion and perfusion effects. Intravoxel Incoherent Motion (IVIM) MRI enables non-contrast separation of these components, offering potential clinical value in neuroimaging. However, clinical translation remains limited due to variability in acquisition and post-processing methods. This systematic review evaluates optimization strategies aimed at improving the accuracy, reproducibility, and clinical utility of IVIM parameters in brain.

Methods

Registered in PROSPERO and conducted according to PRISMA guidelines, a systematic search across five databases was performed. Original peer-reviewed studies focusing on optimization of IVIM acquisition or post-processing in human brain imaging were included, while reviews and studies lacking methodological detail were excluded. Study quality was assessed using a customized QUADAS-2 tool. Due to methodological heterogeneity, an effect direction plot was applied instead of meta-analysis.

Results

Out of 1,668 identified records, 14 studies were included. Acquisition strategies such as optimised b-value sampling, cardiac gating, and advanced sequences reduced parameter variability by up to 40 %. Post-processing methods, including Bayesian fitting, deep learning–based models, and advanced denoising, improved parameter accuracy by up to 99 % and precision by up to 95 %. Effect direction analysis demonstrated significant positive effects on accuracy and clinical utility (p < 0.001) and repeatability (p < 0.05), while scan-time reduction showed no significant benefit (p > 0.05). No study reported gold-standard validation.

Conclusion

Optimization of IVIM acquisition and post-processing enhances parameter robustness and reproducibility in brain MRI, though protocol heterogeneity remains a major obstacle to standardization and clinical adoption.

El texto completo de este artículo está disponible en PDF.

Keywords : Intravoxel incoherent motion, Diffusion MRI, Parameter optimization, b-value sampling, Post-processing


Esquema


© 2026  The Author(s). Publicado por Elsevier Masson SAS. Todos los derechos reservados.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 6 - N° 1

Artículo 100256- mars 2026 Regresar al número
Artículo precedente Artículo precedente
  • 15 Years of optimizers in medical deep learning: A systematic review
  • Selorm Adablanu, Utpal Barman, Dulumani Das
| Artículo siguiente Artículo siguiente
  • EEG-based classification in psychiatry using motif discovery
  • Melanija Kraljevska, Kateřina Hlaváčková-Schindler, Lukas Miklautz, Claudia Plant

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.