Suscribirse

Deep learning-based image reconstruction significantly improves image quality of MRI examinations of the orbit at 3 Tesla - 02/04/26

Doi : 10.1016/j.diii.2025.11.003 
Aurore Sajust de Bergues de Escalup a, 1, , Augustin Lecler a, b, 1, Émilie Poirion a, Caroline Papeix c, Romain Deschamps c, Dan Milea d, Julien Savatovsky a, Loïc Duron a, Emma O’Shaughnessy a
a Department of Neuroradiology, Hôpital Fondation Adolphe de Rothschild, 75019 Paris, France 
b Université Paris Cité, Faculté de Médecine, 75006 Paris, France 
c Department of Neurology, Hôpital Fondation Adolphe de Rothschild, 75019 Paris, France 
d Department of Neuro-Ophthalmology, Hôpital Fondation Adolphe de Rothschild, 75019 Paris, France 

Corresponding author.

Highlights

Deep learning-based image reconstruction significantly increases signal-to-noise ratio and contrast-to-noise ratio of coronal T2-weighted MR images of the orbit obtained at 3 Tesla.
Deep learning-based image reconstruction improves optic nerve sharpness, brain sharpness and overall image quality of coronal T2-weighted and post-contrast fat-saturated T1-weighted MR images obtained at 3 Tesla.
Diagnostic findings, including optic nerve hypersignal, enhancement, atrophy and orbital meningiomas, are preserved on both T2-weighted and post-contrast T1-weighted MR images obtained with deep learning-based reconstruction.

El texto completo de este artículo está disponible en PDF.

Abstract

Purpose

The purpose of this study was to assess the benefit of a deep learning-based image reconstruction (DLBIR) for improving image quality in orbital magnetic resonance imaging (MRI) at 3 Tesla (T).

Materials and methods

Seventy-one patients (48 women and 23 men) with a mean age of 52 ± 19.5 (standard deviation [SD]) years (age range: 7–90 years) who underwent MRI examination of the orbit at 3 T between January and June of 2024, were included in the study. Coronal T2-weighted MR images obtained in 70 patients and post-contrast fat-saturated (FS) coronal T1-weighted MR images obtained in 25 patients, were reconstructed with and without DLBIR, resulting in four imaging sets. Two radiologists independently and blindly measured the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the optic nerves on the four imaging sets. Image quality and orbital abnormalities were assessed using a standardized 5-point Likert scale. Comparisons between MR images obtained with and without DLBIR were performed using Wilcoxon test for ordinal and quantitative variables and McNemar test for paired binary data.

Results

SNR and CNR of coronal T2-weighted MR images were significantly greater using DLBIR (26.67 ± 9.03 [SD], and 14.87 ± 10.31 [SD], respectively) than without DLBIR (18.91 ± 7.28 [SD], and 9.78 ± 8.47 [SD], respectively) ( P < 0.001). There were no differences in SNR and CNR between post-contrast FS T1-weighted images obtained with DLBIR (85.56 ± 63.13 [SD], and 64 ± 41.38 [SD], respectively) and those obtained without DLBIR (91.36 ± 48.49 [SD], and 43.25 ± 20.4 [SD], respectively) ( P = 0.35, and P = 0.14, respectively). Qualitatively, good-to-excellent image quality was obtained more frequently with DLBIR than without DLBIR for T2-weighted and post-contrast FS T1-weighted images with respect to optic nerve sharpness (67 % vs . 16 %, and 8 % vs . 0 %, respectively), brain sharpness (90 % vs . 6 %, and 68 % vs . 4 %, respectively), and overall image quality (73 % vs . 1 % and 36 % vs . 0 %, respectively) (all P ≤ 0.001). No significant differences in the detection rates of orbital abnormalities were found between MR images obtained with and without DLBIR, including optic nerve hyperintensity (34 % vs . 31 %, respectively; P = 0.16) and optic nerve atrophy (33 % for both) on T2-weighted images, and optic nerve enhancement on post-contrast FS T1-weighted images (16 % for both).

Conclusion

DLBIR significantly improves image quality of MRI examinations of the orbit at 3 T, without losing clinically relevant information.

El texto completo de este artículo está disponible en PDF.

Keywords : Deep learning, Deep learning-based image reconstruction, Image processing, Magnetic resonance imaging, Optic nerve

Abbreviations : CNR, DLBIR, FS, ICC, MRI, ROI, SD, SNR


Esquema


© 2025  Société française de radiologie. Publicado por Elsevier Masson SAS. Todos los derechos reservados.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 107 - N° 4

P. 143-150 - avril 2026 Regresar al número
Artículo precedente Artículo precedente
  • Understanding the challenges to implementing AI solutions in radiology departments and how to overcome them: A comprehensive review endorsed by the French College of Radiologists (CERF) and the French Society of Radiology (SFR)
  • Amandine Crombé, Camille Bourillon, Stéphane Chaillou, Clara Bechet, Jules Dupont, Alexandre Bône, Fanny Louvet-de Verchère, Alain Luciani, Marie-France Bellin, Christophe Aubé, Nathalie Lassau
| Artículo siguiente Artículo siguiente
  • Cone-beam CT-guided osteosynthesis of traumatic pelvic fractures: An analysis of 67 patients
  • Hugo Perez, Bastien Chalamet, Sylvain Grange, Anthony Viste, Joris Lavigne, Jean-Baptiste Pialat, Nicolas Stacoffe

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.