Doi : 10.1016/j.ortho.2026.101167 
Sabreen Faseeha, Divya Durairaj, Shanthini Priya Arumugam , Parameswaran TM, Balaji Krishnan, Deepak Prabhu, Mahalakshmi Krishnakumaran
 Department of Orthodontics and Dentofacial Orthopedics, Tagore Dental College And Hospital, Chennai, India 

Shanthini Priya Arumugam, Tagore Dental College And Hospital, Department of Orthodontics and Dentofacial Orthopedics, Rathinamangalam, Melakkottaiyur Post, Near Vandalur, Chennai 600127, India. Tagore Dental College And Hospital, Department of Orthodontics and Dentofacial Orthopedics, Rathinamangalam Melakkottaiyur Post, Near Vandalur Chennai 600127 India

Summary

Objective

The primary objective of the study was to compare surface roughness changes of thermoformed (Zendura™ FLX) and direct-printed aligners (TA 28 resin) after 10 days of intraoral usage. The secondary objective was to evaluate both line and surface roughness changes between used and unused thermoformed and direct printed aligner.

Material and methods

The study included 48 aligner samples divided into four groups: direct printed control, direct printed used, thermoformed control, and thermoformed used ( n = 12 each). Surface roughness was analysed using atomic force microscopy (AFM), measuring parameters such as Sa, Sq, Sy, Sp, Sv for surface roughness and Ra, Rq, Ry, Rp, Rv for line roughness. Shapiro-Wilk test showed non-normal distribution of data. Median values and interquartile ranges were used for descriptive statistics. Median quantile regression analysis was performed.

Results

Direct-printed control aligners demonstrated higher median roughness values (Sa: 57.76 nm) compared to their used counterparts (49.93 nm). In contrast, thermoformed aligners exhibited significantly lower roughness, particularly under used conditions (Sa = 16.85 nm). Direct-printed unused versus used samples showed significant differences ( P 0.05) for Sq and Sv parameters, confirming that usage reduces surface roughness. Similar patterns were observed in thermoformed groups (unused vs. used), with significant reductions in Sa, Sq, and Sy parameters ( P 0.05). Both Direct-printed and thermoformed aligners unused versus used aligners showed significant reductions in Ra, Rq, and Ry parameters ( P 0.05). Both comparisons showed significant positive coefficients for Rv, indicating shallower valleys after use.

Conclusion

Intraoral use led to decreased surface roughness in both aligner types, with thermoformed aligners showing the smoothest surface post-use. These findings have important implications for aligner fit, patient comfort, and potential effects on oral tissues.

El texto completo de este artículo está disponible en PDF.

Keywords : Orthodontics, Appliances, Clear aligners, Aging, Direct printed aligner, Thermoformed aligner


Esquema


© 2026  CEO. Publicado por Elsevier Masson SAS. Todos los derechos reservados.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 24 - N° 3

Artículo 101167- septembre 2026 Regresar al número
Artículo precedente Artículo precedente
  • Professional malpractice claims in orthodontics: A scoping review
  • Giuseppe Varvara, Pierangelo Burdo, Davide Gerardi, Sara Bernardi, Roberta Pasqualone, Giuseppe Perinetti
| Artículo siguiente Artículo siguiente
  • Longitudinal evaluation of salivary biomarkers and white spot lesion development in patients undergoing fixed orthodontic treatment: A prospective cohort study
  • Kunal Jha, Mohammed Ali Hamid Syed, Rajat Sharma, Seema Gupta, Rahul Tiwari, Niti Dharmendra Shah

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.