Irradiation insterstitielle partielle et accélérée du sein de haut débit de dose : résultats préliminaires cliniques et dosimétriques sur 61 patientes - 08/12/08

Doi : 10.1016/j.canrad.2008.09.008 
J.-M. Hannoun-Levi a, , M. Ferré a, I. Raoust b, M. Lallement b, B. Flipo b, F. Ettore c, S. Marcié a
a Département de radiothérapie, centre Antoine-Lacassagne, 33, avenue de Valombrose, 06189 Nice cedex, France 
b Département de chirurgie, centre Antoine-Lacassagne, Nice, France 
c Département d’anatomopathologie, centre Antoine-Lacassagne, Nice, France 

Auteur correspondant.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

páginas 9
Iconografías 2
Vídeos 0
Otros 0

Résumé

Objectif de l’étude

Parmi toutes les techniques d’irradiation partielle et accélérée du sein, la curiethérapie interstitielle de bas puis de haut débit de dose a été la première utilisée. Les résultats préliminaires cliniques et dosimétriques de l’irradiation interstitielle partielle et accélérée du sein de haut débit de dose pratiquée au centre Antoine-Lacassagne de Nice ont été analysés.

Patientes et méthodes

De juin 2004 à mars 2008, 61 patientes, atteintes d’un carcinome mammaire non lobulaire T1-2 pN0, nouvellement diagnostiqué pour 37, en récidive pour 24, ont été traitées par tumorectomie et ganglion sentinelle/curage axillaire avec mise en place peropératoire de tubes plastiques vecteurs pour irradiation interstitielle partielle et accélérée du sein de haut débit de dose. L’étude dosimétrique (avec histogrammes dose–volume) a été faite sur une scanographie réalisée à deux à trois jours après l’opération. Une analyse dosimétrique comparative a été faite entre distributions de dose optimisée et non optimisée. Sur la base du conformal index (COIN), un nouvel indice a été proposé tenant compte à la fois de la conformité et de l’homogénéité de l’implant. Une analyse de l’impact du gradient de dose sur l’équivalence biologique de la curiethérapie interstitielle de haut débit de dose a été menée. Les analyses statistiques ont utilisé le test t de Student, confirmé par le test de Wilcoxon pour les effectifs inférieurs à 30.

Résultats

L’analyse dosimétrique comparative, entre distributions de dose optimisées et non optimisées, a montré que les indices de conformité obtenus après optimisation (conformal index, conformal number et D90 %) étaient tous significativement meilleurs que ceux obtenus sans optimisation. Cette amélioration de la conformité s’est faite au détriment d’une augmentation significative des volumes d’hyperdosage (V150 % et V200 %). Un Indice dit de « conformité et d’homogénéité », tenant compte du V150 %, a permis de pondérer le conformal index. L’équivalence biologique de 34Gy en dix fractions et cinq jours a été calculée à 41,93Gy pour un rapport ⍺/β=4Gy mais à 75,76Gy si le gradient de dose était pris en compte.

Conclusions

La curiethérapie interstitielle de haut débit de dose représente une des meilleures techniques d’irradiation partielle et accélérée du sein avec ses possibilités d’optimisation, de préservation de l’enveloppe cutanée et de détermination du volume cible. De plus, l’impact du gradient de dose représente un atout majeur car une relation dose–effet a été montrée pour ce type de tumeur.

El texto completo de este artículo está disponible en PDF.

Abstract

Purpose

Among all the accelerated and partial breast irradiation (APBI) techniques, low then high dose rate, interstitial brachytherapy (HDIB) was the first to be used in this field. This study presents the preliminary clinical and dosimetric results of the APBI using HDIB, performed in Antoine Lacassagne Cancer Center of Nice.

Patients and Methods

From June 2004 to March 2008, 61 patients (37 primary tumors and 24 second conservative treatments after local recurrence) presenting with T1-2 pN0 non-lobular invasive breast carcinoma, underwent lumpectomy with sentinel lymph node dissection and intraoperative tube placement for HDIB. Dose distribution analysis, using dose–volume histograms, was achieved based on a postoperative CT scan. A comparative dosimetric study was performed between optimized (O) and non-optimized (NO) dose distribution. Then, based on conformal index calculation, a novel index was proposed taking into account not only the conformity but also the homogeneity of HDIB implant. An analysis of dose gradient impact on HDIB biological equivalence dose was also conducted. Statistical analysis used T test confirmed by Wilcoxon test for cohort including less than 30 patients.

Results

The comparative dosimetric analysis between O and NO dose distributions shown that conformity indexes (conformal index, conformal number, and D90 %) were significantly increased after optimization. Improving conformity leads to increasing hyperdosage volumes (V150 % and V200 %). A new index named conformity and homogeneity index (CHI) including V150 % values, modified the conformal index. A total dose of 34Gy, delivered through HDIB in 10 fractions over five days was biologically equivalent to 41.93Gy assuming ⍺/β=4Gy and 75.76Gy if the dose gradient was considered in the calculation.

Conclusions

HDIB is considered as one of the best IPAS technique. HDIB allows dose distribution optimization, skin spearing and accurate clinical target volume definition. Furthermore, HDIB dose gradient could play a key role for breast cancer local control.

El texto completo de este artículo está disponible en PDF.

Mots clés : Irradiation partielle et accélérée, Cancer du sein, Curiethérapie interstitielle, Haut débit de dose

Keywords : Accelerated and partial irradiation, Breast cancer, High dose rate, Interstitial brachytherapy


Esquema


© 2008  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 12 - N° 6-7

P. 532-540 - novembre 2008 Regresar al número
Artículo precedente Artículo precedente
  • Résultats préliminaires de l’étude STIC PDR intitulée « Utilisation de la curiethérapie pulsée gynécologique (PDR) avec optimisation de la répartition de la dose et dosimétrie tridimensionnelle » pour les cancers du col utérin
  • C. Charra-Brunaud, D. Peiffert
| Artículo siguiente Artículo siguiente
  • L’évaluation gériatrique est-elle adaptée à la radiothérapie ?
  • C. Falandry, K. Tarkouki, F. Mornex, M. Bonnefoy, G. Freyer

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
La compra de artículos no está disponible en este momento.

¿Ya suscrito a @@106933@@ revista ?

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.